edge evaluation
0 = one-fold evaluation
P06
1 = two-fold evaluation
2 = four-fold evaluation
change of signs
P07
0 = active; 1 = not active
multiplication factor
multiplication of the input pulses by factor
P08
0.0001 ... 9.9999
(if P11 is set to 4 or 5, only factors ≤ 1.0000 should be
used)
relay function
P10
0 = fleeting; 1 = solid state until reset / preset
output performance of the relay
0 = relay switches at 0
1 = relay switches at preset
2 = relay switches at ≥ preset, de-energises at < preset
3 = relay switches at ≤ preset, de-energises at > preset
P11
4 = relay switches at 0 and sets autopreset
(sets the counter to preset)
5 = relay switches at preset and sets autoreset
(sets the counter to 0)
fleeting time relay
P12
0.1s ... 9.9s adjustable in steps of 0.1s
display brightness
P14
0 ... 9 = level of brightness
external reset / preset
P15
0 = preset if pulse on terminal 13
1 = reset if pulse on terminal 13
basic setting
P16
1 = all parameter values are set to the basic setting
input block for preset
P18
0 = preset can be changed
1 = preset cannot be changed (blocked)
limitation of the counting frequency in the VRD mode
0 = max. counting frequency = 10 Hz
P19
(max. count value: ± 32768)
1 = max. counting frequency = 20 kHz
relay switches if value of the preset value is positive or
P21
negative
0 = active; 1 = not active
P99
display of the current software version and the version number
0
0
1,0000
0
1
1,0
5
1
0
0
1 1
(IN-A = 1
IN-B = 1)