Selection Guide - HEATSTRIP Elegance THE1800EU Manuel D'utilisation, D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Selection Guide

General recommendations for HEATSTRIP Elegance:
• Ideal mounting height: 2.3m to 2.5m. Maximum is 2.7m in a fully protected/enclosed outdoor environment.
• Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)
• Minimum recommended heating capacity for various installations are: 400W/m2 for indoor spot heating; 500W/m2
for protected outdoor areas, and 600W/m2 for exposed outdoor areas. To ensure the HEATSTRIP Elegance provides
satisfactory performance, HEATSTRIP strongly recommends using conservative coverage areas when specifying how
many heaters are required for each installation.
The table below outlines the maximum coverage of each
narios with direct overhead mounting at minimum installation height. For example, for an outdoor area that is protected
from prevailing winds by walls, café blinds etc, Model THE1800 will cover a maximum of 3.6m
cover a maximum of 4.8m
For angled wall mounting applications, the coverage is reduced by up to 40%.
MODEL
INDOOR PROTECTED (m
THE 1800
THE 2400
THE 3600
8
2
.
2
)
OUTDOOR ENCLOSED (m
4.5
6
9
HEATSTRIP Elegance model based on 3 different sce-
2
)
OUTDOOR EXPOSED (m
3.6
4.8
7.2
2
and Model THE2400 will
2
)
3
4
6

Publicité

Table des Matières
loading

Table des Matières