Please install your filter pump following the lnstallation illustration bellow.
LOWER HOSE
CONNECTION
WATER
DIRECTION
CONNECTING
WATER
HOSE
DIRECTION
(INTERIOR DE
PLASTIC
LA PISCINA)
PLASTIC
CLAMP
CLAMP
WATER
DIRECTION
INLET
UPPER
PROTRUDING
HOSE
CONNECTION
OUTLET
OPERATING INSTRUCTIONS
1. The filter pump will prime itself as long as it is positioned at least 20 cm below the highest water
level is a relief valve located on the top of the pump. Simply turn the valve knob counter-clockwise, and
when a small amount of water escapes, close immediately by turning clockwise.
The pump will now be completely primed.
2. Never operate the filter pump dry. This can cause damage to seals which may result in leakage and/
or flooding.
3. Prior to each use, check to ensure that all hose-clamps are tightened.
4. To prevent possible electric shock, do not attempt to plug in electrical power cord with wet hand or
while standing in water.
5. The filter pump must operate in the upright, vertical position.
6. The filter pump must be positioned on level, table ground. And the use of a riser or elevated platform
is not expected.
7. To preserve the full life of the pump and to keep the pool filtered properly, your pump should be run
approximately 4 to 6 hours per day.
8. Overuse may cause overheating and/or motor burnout. Use good judgment on extremely days and be
mindful of running the filter pump continuously for an extended period of time.
CLEANING AND REPLACEMENT
1. The Aqualoon in your pump filter system should be replaced approximately once per season.
2. Periodically cleaning of your Aqualoon can enhance the effectiveness of your filter pump and
moderately prolong the Aqualoon's lifespan prior to replacement.
3. Keep the power be disconnecting to the unit when changing the Aqualoon.
4. Turn the Air Vale Screw to release the air suction inside.
5. Remove the Filter Chamber Cover and the filter chamber rubber gasket, and then take out the
Aqualoon.
6. Your clean (or new) Aqualoon can be put back into the filter chamber and you can refer to the
installation instruction to re-assemble the filter pump unit.
GENERAL MAINTENANCE
1. To avoid dangerous or fatal electrical shock hazard, always disconnect power to the unit before
attempting to clean pump.
2. There is no need for any regular mechanical maintenance of the pump unit. (Do not attempt to
disassemble the pump motor at any time).
3. If necessary, clean outside of pump with a mild detergent and water, rinsing off with a hose.
4. There is no need for the use of any lubricants on the pump.