ADJUSTING THE VALVES
If the pressure in the gas supply (natural gas or butane gas) differs from that
specified for the gas plate, it may happen that the flame is irregular or goes out,
in which case the adjustment of the valve would have to be regulated, To do
this, follow the following process:
1.
Turn on the cooking zone you wish to adjust and wait approximately 10 minutes for
the safety sensor to be completely hot.
2.
Turn the knob counterclockwise to the position (
3. The flame must not be switched off or moved
to the burner, if it is switched off or moves
towards the burner it will be necessary to
readjust the valve.
4. To access the valve reset screw, remove the
button corresponding to the cooking zone you
wish to adjust by pulling it upwards.
5. Using a fine flat-blade screwdriver, readjust the
screw on the top left of the valve.
6. Repeat steps 1 to 5 with the other cooking
zones.
Adapting to different types of gas
Appliance category: I
II
ELWLS3B/P II
2
Size
Type
of the
of gas
burner
Natural
G20
Auxiliary
(Small)
Butane
G30
Natural
Semi fast
G20
(Medium)
Butane
G30
Natural
G20
Triple ring
(Big)
Butane
G30
I
I
2H
2E
2E+
ELL
B/P
2
3
Pressure
Nozzle
mbar
diameter
20
0.71
30
0.52
20
0.97
30
0.67
20
1.25
30
0.93
I
I
I
I
2L
2HS
2ELS
2ELW
Nominal charge
g/h
l/h
-
95
72,6
-
-
171
130,8
-
-
323
247
-
12
) minimum flame level.
I
I
I
I
3+
3B/P
3P
2H3+
kW
Kcal/h
1,0
860
1,0
860
1,8
1548
1,8
1548
3,4
2924
3,4
2924
II
I
2E3B/P
2HS3B/P
Reduced
charge
kW
Kcal/h
0,4
344
0,4
344
0,6
516
0,6
516
1,5
1290
1,5
1290