7
ASSEMBLY OF THE ACCELERATOR AND CONNECTION OF THE
"DEAD MAN" SAFETY SYSTEM
Power trowels TIFÓN 120X are supplied with the accelerator and the "dead man" safety system
disassembled, so they must be assembled and connected before working. To do this, firstly it is
necessary to connect the accelerator cable to the engine. Remove the cover of the filter and then
remove the filter. Fix the accelerator cable cover with its clamp (as shown in the picture below) and
put the accelerator cable into the prisoner of the engine:
1 REMOVE THE
AIR FILTER COVER
Once the accelerator is assembled, connect the "dead man" safety system as shown in the picture:
1 DISCONNECT THE BLACK
WIRE FROM THE SPARK
PLUG.
To check the "dead man" safety system works correctly, start the engine with the lever of the safety
system pulled. Once the machine is working, release the lever; the machine must stop working. If the
machine doesn't stop working, check again the connections of the safety system.
TROWELS TIFON 600/900/1200 WITH PETROL ENGINE
3 ATTACH
2 REMOVE THE AIR
THROTTLE SIRGA
FILTER
2 CONNECT THE RED CABLE
WITH THE MOTOR CABLES
THE
4 ATTACH THE
THROTTLE COVER
3 CONNECT THE EARTH GROUND
TO THE MOTOR SCREW
en
13