Electrical Requirements; Important - Emerson HF1160BQ02 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BP7272-4 HF1160.qxp_BP7272 9/10/15 9:44 PM Page 4
This Manual Is Designed to Make it as Easy as Possible for
You to Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One stepladder
One wire stripper
Drill
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be a
3-conductor (2-wire with ground) of following size:
Installed Wire Length
Up to 50 ft.
50-100 ft.
IMPORTANT: Your ceiling fan will not function
properly, and may be damaged, if used with any wall
dimmer switch or control other than an Emerson
Electric Fan Wall Control.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
1. Unpacking Instructions
Materials
Wire Size A.W.G.
14
12

2. Electrical Requirements

WARNING
!
WARNING
!
(Continued)
WARNING
!
Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 10). If you feel
you do not have enough wiring knowledge or experience,
have your fan installed by a licensed electrician.
The outlet box must be securely anchored and capable of
withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture, turn
electricity off at the main fuse box at this time and remove
the existing light fixture.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
Please
call
Emerson
1-800-654-3545 if you have any questions about
installation and operation of this ceiling fan.
4
technical
support
at
U.L. Model No.: HF1160-2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hf1160bs02Hf1160ww02

Table des Matières