Cleaning And Care; Product Registration; Replacement Parts; Limited Warranty - Endless Summer GAD1497SP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
Operating Instructions (continued)
8.
After the fire table lights, continue to hold the control knob in for 20 seconds to heat the
thermocouple, a safety device that stops the gas flow when a firepit is not lit. Holding the
knob in for 20 seconds warms it up so the gas flow will continue.
9.
After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height.
10. After three attempts, if ignition does not occur, turn the burner control knob to " OFF."
11. Wait 5 minutes, fan with a newspaper or magazine, and repeat lighting procedure.
12. If igniter does not light burner:
a.
Wearing heat-resistant gloves, position a long lit match or long lit butane lighter near
the pilot housing.
b.
Push and turn control knob to (LOW).
c.
Remove match/lighter once burner is lit.
W CAUTION: After lighting - using a fire table tool and heat-resistant
gloves, carefully move the glass rocks back to their proper position,
being careful to avoid the flame.
13. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height
matches illustration (Figure 5).
W CAUTION: If ignition does not occur in 5 seconds, turn control knob
to " OFF," wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting procedure.
Turning Off
1.
Turn LP gas tank valve to "CLOSED."
2.
Turn control knob to the " OFF" position.
Note: A "poof" sound is normal as the last of the LP gas is burned.
3.
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section.

Cleaning and Care

W CAUTION:
1. All cleaning and maintenance should be done when outdoor fire
table is cool and with the fuel supply disconnected.
2. Do NOT clean any outdoor fire table part in a self-cleaning oven.
The extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
valves or burners.
Notices
1.
This outdoor fire table should be thoroughly cleaned and inspected on a regular
basis.
2.
Abrasive cleaners will damage this product.
3.
NEVER use oven cleaner to clean any part of this outdoor fire table.
Before Each Use:
1.
Keep the outdoor fire table area clear and free from any combustible materials, gasoline,
and other flammable vapors and liquids.
2.
Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air.
3.
Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.
4.
Visually check the burner flames to make sure your outdoor fire table is working properly
(Figure 5).
5.
See below for proper cleaning instructions.
6.
Check all gas connections for leaks.
7.
Check components for any signs of damage or rust.
8.
Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner/venturi tube can lead to a fire.
9.
If damage to any component is detected, do NOT operate until repairs are completed.
Cleaning Surfaces
1.
Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.
2.
For stubborn stains, use a citrus-based cleaner and a nylon scrubbing brush.
3.
Rinse clean with water.
4.
Allow to air dry.
Cleaning Burner
W WARNING: All cleaning should be done when appliance is cool and
with the fuel supply disconnected per "Disconnecting LP Gas Tank."
1.
Remove the fire glass
2.
Remove all dirt/dust from the burner, igniter cover and venturi area with a small brush and/
or compressed air.
3.
Visually inspect the burner for any rust or damage. If damage is found, replace necessary
parts with new from the manufacturer.
4.
Clean any clogged burner ports with a stiff wire (such as an opened paper clip).
5.
Carefully replace the fire glass being cautious not to block the igniter cover.
LP Gas Outdoor Fire Table
Model No. GAD1497SP
Before Storing
1.
Turn LP gas tank valve to "CLOSED."
2.
Turn control knob to the " OFF" position.
Note: A "poof" sound is normal as the last of the gas is burned.
3.
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section.
4.
Clean all surfaces.
5.
Lightly coat the burner with cooking oil to prevent excess rusting.
W CAUTION: NEVER place cover on hot outdoor fire table.
6.
If storing the outdoor fire table indoors, cover the outdoor fire table and store in a cool dry
location away from children and pets.
7.
If storing the outdoor fire table outdoors, cover the outdoor fire table with a cover for
protection from the weather.

Product Registration

For faster warranty service, please register your product immediately. To register, go to
BlueRhino.com/warranty or call 1.800.762.1142.

Replacement Parts

For replacement parts, call 1.800.762.1142.

Limited Warranty

Blue Rhino Global Sourcing, Inc. ("Blue Rhino") warrants to the original retail purchaser of this
product, and to no other person, that if this product is assembled, maintained, and operated
in accordance with the printed instructions accompanying it, then for a period of one (1) year
from the date of purchase, all parts in such product shall be free from defects in material and
workmanship. Blue Rhino may require reasonable proof of your date of purchase. Therefore,
you should retain your sales slip or invoice. This Limited Warranty shall be limited to the repair
or replacement of parts, which prove defective under normal use and service and which Blue
Rhino shall determine in its reasonable discretion upon examination to be defective. Before
returning any parts, you should contact Blue Rhino's Customer Care Department using the
contact information listed below. If Blue Rhino confirms, after examination, a defect covered
by this Limited Warranty in any returned part, and if Blue Rhino approves the claim, Blue Rhino
will replace such defective part without charge. If you return defective parts, transportation
charges must be prepaid by you. Blue Rhino will return replacement parts to the original retail
purchaser, freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties due to accident,
abuse, misuse, alteration, misapplication, improper installation or improper maintenance or
service by you or any third party, or failure to perform normal and routine maintenance on
the product as set out in this owner's manual. In addition, the Limited Warranty does not cover
damage to the finish, such as scratches, dents, discoloration, rust or other weather damage,
after purchase.
This Limited Warranty is in lieu of all other express warranties. Blue Rhino disclaims all
warranties for products that are purchased from sellers other than authorized retailers or
distributors, including the warranty of merchantability or the warranty of fitness for a particular
purpose. Blue Rhino ALSO DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. Blue Rhino SHALL HAVE NO LIABILITY TO PURCHASER OR ANY THIRD
PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
Blue Rhino further disclaims any implied or express warranty of, and assumes no responsibility
for, defects in workmanship caused by third parties.
This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other
rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or
limitation of special, incidental or consequential damages, or limitations on how long a warranty
lasts, so the above exclusion and limitations may not apply to everyone.
Blue Rhino does not authorize any person or company to assume for it any other obligation
or liability in connection with the sale, installation, use, removal, return, or replacement of its
equipment, and no such representations are binding on Blue Rhino.
Blue Rhino Global Sourcing, Inc.
Winston-Salem, North Carolina 27105 USA
1.800.762.1142
Need help? 1.800.762.1142
Do not return to place of purchase.

Troubleshooting

Problem
Possible Cause
LP gas tank valve is closed
LP gas tank is low or empty
LP gas leak
Battery needs to be changed
Burner will not light using igniter
Electrode and burners are wet
Electrode cracked or broken - sparks at crack
Wire loose or disconnected
Wire is shorting (sparking) between igniter and electrode Replacement part(s) may be needed - contact Customer Care at 800.762.1142
Bad igniter
No gas flow
LP gas tank is low or empty
LP gas leak
Burner will not light with match
Coupling nut and regulator not fully connected
Obstruction of gas flow
Disengagement of burner to valve
Spider webs or insect nest in burner/venturi tube
Burner ports clogged or blocked
Out of gas
Sudden drop in gas flow or reduced flame height
Overfilling prevention device may have been activated
Irregular flame pattern, flame does not run the
Burner ports are clogged or blocked
full length of burner
New burner may have residual manufacturing oils
Flame is yellow or orange
Spider webs or insect nest in burner/venturi tube
Poor alignment of valve to burner/venturi tube
High or gusting winds
Flame goes out
Low on LP gas
Excess flow valve tripped
Flashback (fire in venturi/burner tube(s))
Burner and/or burner/venturi tube is blocked
Flame seems to lose heat when burning in cold
Ice has built up on the outside of the LP gas tank
weather - temperature below 50ºF
because the vaporization process is too slow
For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.
Replacement Parts
9
1.800.762.1142
Prevention/Cure
Make sure regulator is securely attached to the LP gas tank per "Installing LP
Gas Tank," then turn LP gas tank valve to "OPEN"
Exchange, refill or replace LP gas tank
1.
Turn LP gas tank valve to "CLOSED"
2.
Wait 5 minutes for gas to clear
3.
Follow "Checking for Leaks" section
Replace the "AA" battery (follow assembly step for inserting battery)
Wipe dry with cloth
Replacement part(s) may be needed - contact Customer Care at 800.762.1142
Reconnect wire or replacement part(s) may be needed - contact Customer Care
at 800.762.1142
Replacement part(s) may be needed - contact Customer Care at 800.762.1142
Check if LP gas tank is empty
a.
If empty, exchange, refill or replace LP gas tank
b.
If LP gas tank is not empty, refer to "Sudden drop in gas flow or
reduced flame height" (see below)
Exchange, refill or replace LP gas tank
1.
Turn LP gas tank valve to "CLOSED"
2.
Wait 5 minutes for gas to clear
3.
Follow "Checking for Leaks" section
Turn the coupling nut about one-half to three-quarters additional turn until solid
stop. Tighten by hand only - do NOT use tools
1.
Clear burner/venturi tube
2.
Check for bent or kinked hose
Re-engage burner and valve
Clean burner/venturi tube
Clean burner ports
Exchange, refill or replace LP gas tank
1.
Turn control knob to " OFF"
2.
Wait 30 seconds and light outdoor fireplace per "Lighting" section
3.
If flames are still too low, reset the overfilling prevention device:
a.
Turn control knob(s) " OFF"
b.
Turn LP gas tank valve to "CLOSED"
c.
Disconnect regulator
d.
Turn control knobs to (HIGH)
e.
Wait one minute
f.
Turn control knobs to " OFF"
g.
Reconnect regulator and leak check connections, being careful not to
fully open valve
h.
Light outdoor fireplace per "Lighting" section
Clean burner ports
Burn outdoor fireplace for 15 minutes and reinspect
Clean burner/venturi tube
Ensure burner/venturi tube is properly engaged with valve
Do not use outdoor fireplace in high winds
Exchange, refill or replace LP gas tank
Refer to "Sudden drop in gas flow or reduced flame height"
Clean burner and/or burner/venturi tube
1.
Turn off per "Turning Off" section
2.
Replace with a spare LP gas tank
3.
Reconnect LP gas tank per "Installing LP Gas Tank" section
4.
Follow "Checking for Leaks" section
5.
Light outdoor fireplace per "Lighting" section