Installing Lp Gas Tank; Operating Instructions - Endless Summer GAD1497SP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6
Assembly Instructions (continued)
5
Attach Door
B
x 1
7
Place Lava Rocks (sold separately)
W CAUTION: Do NOT dump lava rocks out of package. Carefully
place lava rocks by hand so dust does not clog burner.
W CAUTION: Use only Blue Rhino Global Sourcing, Inc. factory-
authorized lava rock. The use of any lava rock that is not
factory-authorized can be dangerous and will void your
warranty.
W CAUTION: Do NOT cover pilot housing.
Note: Lava rocks should be 0.8-2.0 in. (2-5 cm) long. Approx. 5.95 lbs. (2.7 kg) of
lava rocks are needed.
LP Gas Outdoor Fire Table
Model No. GAD1497SP
6
Place Glass Rocks
W CAUTION: Do NOT dump glass rocks out of package. Carefully
place glass rocks by hand so dust does not clog burner.
W CAUTION: Use only Blue Rhino Global Sourcing, Inc. factory-
authorized glass rock. The use of any glass rock. that is
not factory-authorized can be dangerous and will void your
warranty.
W CAUTION: Do NOT cover pilot housing.
Note: Glass rocks should be 0.4-1.2 in. (1-3 cm) long. Approx. 13.2 lbs. (6 kg) of
glass rocks are needed.
Need help? 1.800.762.1142
Do not return to place of purchase.

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W CAUTION: LP gas tank must be properly
20 lb
disconnected and removed prior to moving this
9 Kg
outdoor fire table.
Inserting LP Gas Tank
12.2 in. / 31 cm
W WARNING: Make sure LP gas tank valve is closed.
1.
Open door.
2.
Loosen LP gas tank retainer bolt by turning counter-clockwise.
3.
Place precision-filled LP gas tank upright into hole in outdoor fire table base so the tank
valve is facing the gas line connection.
4.
Secure tank by turning LP gas tank retainer bolt clockwise until tight.
5.
Close door.
Connecting LP Gas Tank
1.
Make sure control knobs are in the " OFF" position
(Figure 3).
2.
Before connecting, be sure there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner or burner ports.
3.
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops.
4.
Perform leak check per "Checking for Leaks" section
Disconnecting LP Gas Tank
1.
Make sure control knobs are in the " OFF" position
(Figure 3).
2.
Before disconnecting, make sure the LP gas tank valve is
"CLOSED."
3.
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving
this grill.
4.
Place the protective cap cover on the LP tank and store the tank outdoors in a well
ventilated area out of direct sunlight.
BlueRhino.com
Available in U.S. only.
Replacement Parts
1.800.762.1142

Operating Instructions

Figure 1
Checking for Leaks
LP Gas
W WARNING: Before using this outdoor
Connection
fire table, make sure you have
read, understand and are following
all information provided in the
"Important Safeguards" section
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
W WARNING: The burner must be
replaced prior to the appliance being
put into operation if it is evident
that the burner is damaged. The
replacement burner shall be that
Figure 2
specified by the manufacturer.
Burner Connections
X
1.
Make sure the regulator hose and valve
connections are securely fastened to the burner
X
and the tank.
X
2.
Visually check the connection between the
X
burner/venturi tube and orifice.
3.
Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect
Figure 3
this connection or follow these
instructions could cause a fire or an
OFF / ARRÊT
explosion which can cause death,
serious bodily injury or damage to
property.
4.
Please refer to diagram for proper installation
(Figure 1).
5.
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1.800.762.1142 for assistance.
Tank/Gas Line Connection
1.
Make 2-3 oz. of leak detection solution by
Figure 4
mixing one part liquid dishwashing soap with
three parts water.
2.
Make sure control knobs are in the " OFF"
position (Figure 3).
3.
Connect LP gas tank per "Installing LP Gas
Tank" section.
4.
Turn LP gas tank valve to "OPEN."
5.
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2).
a. If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test.
b. If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
Figure 5
"Disconnecting LP Gas Tank" section. Contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, turn
15.75 in – 19.7 in
LP gas tank valve to "CLOSED," wipe away
40-60 cm
solution and proceed.
Lighting
W WARNING: NEVER light the burner
with the cover on the outdoor fire
table.
W CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1.
Make sure all labels, packaging and protective films have been removed from the outdoor
fire table.
2.
Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3.
Control knob must be in the " OFF" position (Figure 3).
4.
Clear small area of glass rocks away from the igniter cover (Figure 4).
5.
Connect LP gas tank per "Installing LP Gas Tank" section.
6.
Turn LP gas tank valve to "OPEN."
7.
Push and turn control knob to (HIGH). Continue to hold the control knob in to light.
7
LP Gas Valve
with Orifice
X

Publicité

Table des Matières
loading

Table des Matières