NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
• Do not expose the control panel to moisture, snow
or rain.
• Protect from freezing.
• Store and transport securely to avoid any damaging
impact to internal parts.
• Secure during transport to prevent sliding and possi-
ble injury to vehicle occupants.

MAINTENANCE SCHEDULE

WARNING! ELECTRIC SHOCK HAZARD. Unplug unit
before cleaning or servicing.
WARNING: Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous contami-
nants, clean thoroughly and sanitize before reuse.
NOTICE: The unit is fitted with sensitive electronic sen-
sors. Protect the sensors and their lead wires from dam-
age and do not expose them to water or cleaning solu-
tion.
The following tools and supplies are needed to com-
plete the maintenance procedures described in this
manual:
Philips screwdriver
10 mm wrench
6 mm hex bit
¼ in. nut driver
Cleaning cloths
HEPA vacuum cleaner with soft brush nozzle and
crevice nozzle.
110482P (07-01913) #103806 (F515)
Recommended
Cordless drill, small knife, small-jaw pliers, coil clean-
ing solution, rotomolded housing cleaning solution.

Before each use

Inspect the electrical cord for damage. Look for fray-
ing, cuts, etc. Replace the cord if you find any damage.
Inspect filter. The PHD 200 filter should be replaced
when the accumulation of dust is visible.
Monthly
Clean pump check valve and basin. In normal use,
dust can accumulate and can restrict airflow, reducing
performance and causing the unit to overheat. Clean
when dust accumulation is visible. Remove grills and
cover as shown in Fig. B. Use a vacuum cleaner with a
brush tool and a soft cloth to remove any debris. Take
care not to damage any interior components.
To maintain appearance, wipe interior and exterior sur-
faces with a damp cloth. For deep cleaning and a last-
ing, protective shine, use an automotive interior cleaner.
As Needed
Clean pump check valve and basin. Remove grills and
cover as shown in Fig. B. Remove screws from pump
base and lift out pump. Wipe out pump basin with a
damp cloth. Unthread barbed fitting with check valve and
rinse fitting and check valve with clean water. Reinstall
barbed fitting into pump. Do not overtighten. Reinstall
pump on base. Reinstall cover and grills.
Clean coils. With the cover removed, inspect both coils.
If excessive dust and debris is present, vacuum thor-
oughly and/or clean with coil cleaner.
Fig. B: Disassembly for Cleaning
Remove the 4 screws
from housing and 2
top screws each from
inlet and outlet grills
and lift off cover.