LOCATION AND INSTALLATION/VENTILATION
INSTALLATION CLEARANCES 36" WITH ISLAND TRIM
EN
NOTES:
•
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
•
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
•
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
•
"E" IS ELECTRICAL SUPPLY ZONE.
•
"W" IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8" BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
•
"V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
12
©2021 Hestan Commercial Corporation
COMBUSTIBLE
V
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
9-1/2"
[24.1]
18"
G
[45.7]
19"
[48.3]
3"
ELECTRICAL
[7.6]
SUPPLY
LOCATION
5"
[12.7]
FRONT VIEW
MATERIALS
W
E
6"
[15.2]
2-1/2"
[6.4]
5"
[12.7]
RANGE MODEL
KRD365/KRDS365
KRD364GD
(CONTINUED)
12"
[30.5]
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COUNTERTOP
FULL OVERLAY
DRAWER FACE
1
" [3.2 mm]
8
FULL OVERLAY
CABINET DOOR FACE
DIMENSIONS IN
BRACKETS [ ]
ARE IN CM.
FINISHED
FLOOR
W
V
(MIN)
36" [91.4]
30" [76.2]
36" [91.4]
30" [76.2]