6.) From the roomside, a lign TRIM RING notch to vent (DAMPER) position. Attach
TRIM RING to FAN. Attach the SHIELD by squeezing the mounting springs
together and inserting the springs into the spring guides in the FAN.
mounting springs
Care and Cleaning
WARNING: To reduce the risk of electric shock, fire, or injury to persons,
disconnect or turn off the breaker and lock the power supply at the panel to
prevent the power from being turned on before servicing or cleaning the unit.
1.) Remove the SHIELD by squeezing the springs and pulling down.
2.) Wash and clean the SHIELD in a sink and dry with a cloth.
3.) Remove dust and dirt from the FAN housing with a vacuum cleaner.
4.) Dampen cloth with dish detergent and wipe the FAN housing and dry with a
cloth.
5.) Replace the SHIELD.
SHIELD
13
ceiling
FAN
TRIM RING