3.4.2
SMS commands overview
Command
Parameter
alert
alert
on
alert
off
alert
state
alert
state
battery
gsm
ip
eth
ip
eth dhcp
ip
eth dhcp
ip
eth addr
ip
eth mask
ip
eth gw
ip
eth dns1
ip
eth dns2
log
log
period
log
extra
log
extra
sms
sms
limit
sms
reset
vebus
vgr
10
Argument
Description
Requests the current alert configuration.
Enables alerts, and sets the alert number to
the number of the device that sent the
message (up to 5 distinct numbers could be
specified)
Disables alerts for number.
Starting from release 2.02. Enables reporting
on
system state changes (on battery/AC input
power on); This will work if alerts are on.
Starting from release 2.02. Disables
off
reporting system state changes (on
battery/AC input power on). This is a default
setting.
Requests information about the battery.
Requests information about the GSM
network connection, including the signal
strength.
Requests current IP settings for Ethernet
Enables automatic IP Configuration via
on
DHCP
Disables automatic IP Configuration via
off
DHCP
Sets the static IP address
<value>
Sets the subnet mask
<value>
Sets the default gateway
<value>
Sets the primary DNS server
<value>
Sets the secondary DNS server
<value>
Requests the current logging period for web
mode.
Sets the logging period for web mode (in
<period>
minutes).
Starting from release 2.02.Enables sending
on
more data to logging webserver when
alarm/warning in VE.Bus system occurs.
Starting from release 2.02.Disables sending
off
more data to logging webserver when
alarm/warning in VE.Bus system occurs.
This is the default setting.
Request the amount of SMS messages sent
and the limit.
Sets the maximum SMS messages per day
<limit>
to value.
Resets the counter to zero to allow
responses again.
Requests information about the VE.Bus
system.
Requests information about the version of
the VER.