If the zone management is selected, the available parameters are:
− Name. Shows the name of the zone.
− Zone address. Defines the number of the zone within your installation.
− Linked zones. It displays the control outputs associated.
− Master. Use this parameter to define the thermostat as Master or Zone.
− Basic mode. The thermostats can be set in Basic or Advanced mode.
ES
These are the parameters you can control in basic mode: On/Off, Set-point
temperature, Fan Speed and Operation mode.
− Offset. Allows you to correct ambient temperature that is measured in the
EN
various areas or in all of them, due to deviations by sources of heat/cold
nearby, with a correction factor between - 2,5ºC and 2,5ºC in steps of 0,5ºC.
− Master address. This menu allows you to determine the operation mode of
ES
operation defined in a different master zone.
− Stages. This parameter is used to configure both cooling and heating stages in
a single zone or in all the zones. These are the features to be configured:
IT
PT
DE
− Inputs. It determines the state of the module of a zone based:
− Information. This parameter provides information about the zone and the
42
o
Air. It activates the heating/cooling air in the zone.
o
Radiant. It activates radiant heating/cooling.
o
Air+Radiant. It activates both air and radiant heating/cooling in the
zone selected and also allows the user to select the desired heating
stage.
o
Window. This option allows the control the state of a zone module
based on the opening of the window. It only has effect on the control
element of the zone module. When this contact is on, if it detects any
open window, it turns off the zone after 60 seconds (displaying an
Open window notification on the thermostat). In order to activate
this feature, configure it as Normally open or Normally closed.
o
Presence. It determines the state of the module of a zone based on
the occupancy. It only has effect on the zone control module if it is
associated to a thermostat (it does not operate in secondary zone
modules). When this contact is on, if the zone is empty for over 5
minutes, the Sleep 90 feature is activated (displaying an Occupancy
notification on the thermostat). In order to activate this feature,
configure it as Normally open or Normally closed.
connected element.