Resistance Measurement; Continuity Check; Capacitance Measurement - Textron GREENLEE CM-1360 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.800.544.2843
Typical Measurements and Accuracy (cont'd)
Resistance
Measurement
Ω
Resistance
Range
Accuracy
600.0 Ω
± (1.0% + 0.5 Ω)
6.000 kΩ
± (1.0% + 0.005 kΩ)
60.00 kΩ
± (1.0% + 0.05 kΩ)
Open Circuit Voltage (typical): 1.7 VDC
Capacitance
Measurement
Capacitance
Range
Accuracy*
200.0 μF
± (2.0% + 0.4 μF)
2500 μF
± (2.0% + 4 μF)
* For film capacitors (capacitors with
negligible dielectric absorption).
14
www.calcert.com
15
10
20
5
25
0
30

Continuity Check

SELECT
Continuity
Tone Threshold: Between 10 Ω and 250 Ω
Response Time: Approximately 32 ms
Diode
Measurement
Reverse Bias
Forward Bias
Diode Test
Measuring Range: 2.000 V
Accuracy: ± (1.5% + 0.005 V)
Test Current (typical): 0.3 mA
Open Circuit Voltage (typical):
< 3.5 VDC
SELECT
SELECT