Wiring Diagram:
DM8000
Parameter Configuration:
Parameter
Value
10
5
20
35
21
400
22
10
25
3
NC2
P1-1
C2
P1-2
NO2
P1-3
NC1
P1-4
C1
P1-5
NO1
P1-6
N
P1-7
L
P1-8
COM
P1-9
+5V
P1-10
S1
P1-11
S2
P1-12
Up/Down Counter Mode
Because the initial values were 40 revolutions per 3.5 inches of platform motion, each is
multiplied by 10 to give an even number to increase accuracy since the display can be
programmed in whole numbers. Additionally, because of the decimal point position, the
Display Reference is multiplied by 10 to generate the proper display format. Without the
second multiplication by 10, the display would only read 3.5 inches when the drive motor
turned 400 revolutions.
In count mode, the Reference RPM is set in revolutions. 400 has been entered here to
represent 40 revolutions and the Display Reference has also been multiplied by 10 to yield
whole numbers.
Pulses per revolution of shaft encoder or pickup is 10 PPM
Decimal point position set to XXX.X on display
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
2 Amp
AC Line Input 85-265VAC, 50-60 Hz
black
red
white
brown
Notes
21
Dart PU-20EQUAD
or
Equivalent