Application Examples; Pump Flow Monitor With Audible And Visual Alarm - DART Controls DM8000 Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pump Flow Monitor with Audible and Visual Alarm

Description:
A pump monitor which displays the pump rate in gallons per minute with an audible and visual
alarm output which will warn the operator of excessively low flow conditions under 5.00 GPM.
The alarm should not be able to be silenced and should be reset when any front-panel button
is pressed. The display should indicate in the format "xx.xx" (GPM). Due to normal fluctuations
in flow rates, it is desirable to have the display filter or average the value over 3 seconds to
produce a more accurate and steady display.
Application Diagram:
Page
Ite
Valu
Tach
m
ENTER
36.24
TACHOMETER
Dart DM8000 Meter
Wiring Diagram:
DM8000

Application Examples

Dart 253G or other Motor Control
4
Motor
2
0
Dart Pue-20
or other Encoder
Audible
Annunciator
NC2
Not Used
P1-1
C2
Not Used
P1-2
NO2
Not Used
P1-3
NC1
P1-4
Not Used
C1
P1-5
NO1
P1-6
N
P1-7
L
P1-8
COM
P1-9
+5V
P1-10
S1
P1-11
S2
P1-12
Not Used
16
6
8
ON
OFF
10
Pump Specs:
2 Amp
black
red
white
Fluid
Outlet
Fluid
Inlet
Pump
53 Shaft Rotations = 3 Gallons
120VAC
Audible
Annunciator
AC Line Input 85-265VAC, 50-60 Hz
Dart PU-10E or
Equivalent
Encoder

Publicité

Table des Matières
loading

Table des Matières