GB
CHARGING INDICATION
When the charger is being used, it shows LED lights as follows, indicating the status of the charging.
NO AC Power (all lights off)
There is no AC power applied. Check the AC end.
STAND BY (green blinking only)
The clamps are not connected to battery properly.
CHARGING (green & red lit)
The charger is charging the battery.
DEEPLY DISCHARGED BATTERY (yellow blinking, green & red lit)
It takes more time to charge a deeply discharged battery. The indication goes to "yellow
(defective battery)" after 36 hours' charging.
DEFECTIVE BATTERY (yellow lit only)
The battery cannot hold a charge. Immediate replacement is recommended.
75% CHARGED (green lit & red light blinking)
The battery is 75% charged and ready for load test or can be returned to serve.
FULLY CHARGED (green lit only)
The battery is fully charged. The charger will shift to the maintenance mode.
TROUBLESHOOTING
1. Problem: No LED lit.
Possible Cause: AC end is not making a good connection.
Solution: Check for poor connection at AC side.
2. Problem: Green LED keeps blinking.
Possible Cause: Clamps are not making a good connection.
Solution: Check for poor connection at battery and frame.
3. Problem: Yellow LED illuminated right away when connecting
onto a battery. Possible Cause:
a. Incorrect battery voltage.
b. Battery is at full charge capacity
Solution:
a. Determine if the battery is a 12V battery. The charger will give you a warning if you are connect-
ing to the incorrect application.
b. The battery is currently at full charge and will continue in maintenance/float mode until voltage
drop occues. At the time of voltage drop, charger will resume in maintenance charging mode.
NOTE that if the troubleshooting cannot fix the issue you have, please contact the distributor for the
information.