Pentair PENTEK INTELLIDRIVE PID10-01 Manuel D'installation Et D'utilisation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Figure 4 - Cover And Backplate Gap
6.
To reattach the Intellidrive cover, hook the top of it on
backplate (be sure to leave a gap). Lower bottom of cover
into place. Push cover evenly against backplate, eliminating
the gap. See Figure 7.
7.
Replace screw at bottom of front cover.
Figure 5 - Pull Cover
PN957 (25-06-20)
Typical
230VAC
Circuit
Breaker
(Double
Width)
Figure 6 - Seperate Cover And Back
WIRING
To allow for ease of wiring, the enclosure wiring area is free
of electronics other than the terminals. Conduit holes and
knockouts are located so that the wire can be fed straight
through to the connectors, with minimal bending. The terminals
accept 6-14 AWG wire.
Installations that require larger wire gauge than 6 AWG
will require an external junction box. Run 6 AWG wire from
the Intellidrive into the junction box, then make external
connections with wire nuts to appropriately sized wire.
For convenience in wiring, the input and motor terminals
NOTE:
unplug from the box. Pull them down to remove them for ease of
access (Figure 8).
Verify that the terminal connectors are completely seated when
you replace them. It is best practice to connect all output wires
(larger wire gauge) first, then all input wires.
5997 0412