Operating Conditions & Requirements - Leyco IQsoft IQ-CS Instructions D'installation & Emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
OPERATING CONDITIONS & REQUIREMENTS
OPERATING PRESSURE MIN-MAX: 1,4-8,3 bar / 20-120 psi
 this appliance is configured to perform optimally at an
operating pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a
lower or higher operating pressure the performance may be
affected negatively!
 check water pressure regularly; it may fluctuate severely
depending on the time of day, the day of the week or even the
season of the year.
 take into account that night time water pressure may be
considerably higher than day time water pressure.
 install a pressure reducer ahead of the appliance if necessary.
 install a pressure booster, if it is likely that water pressure may
drop below the minimum.
OPERATING TEMPERATURE MIN-MAX: 2-48 °C / 35-120 °F
 do not install the appliance in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
 the appliance cannot be exposed to outdoor elements, such as
direct sunlight or atmospheric precipitation.
 do not install the appliance too close to a water heater; keep at
least 3 m (10 ft) of piping between the outlet of the appliance
and the inlet of the water heater; water heaters can sometimes
transmit heat back down the cold pipe into the appliance;
always install a check valve at the outlet of the appliance.
ELECTRICAL CONNECTION:
 the appliance only works on 24 VDC; always use it in
combination with the supplied transformer.
 make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.
Page 5
EN - English

Publicité

Table des Matières
loading

Table des Matières