11.7
Climatic Conditions
Operating temperature: -20°C ... +65°C
Storage temperature:
Relative humidity:
Altitude:
11.8
EMC
Noise immunity:
Noise emission:
11.9
Device Safety
Design to:
Protection Class:
Only the front side is classified as
accessible for the operator.
Application area:
Insulation:
Signal inputs and und sensor power supply: SELV
12 Dimensional Drawings
Dimensions in mm [inch]
+0.8
Panel cut-out: 92
Page 20
-25°C ... +75°C
R.H. 93 % at +40°C,
non-condensing
up to 2000 m
EN61000-6-2
with shielded signal and
control cables
EN55011 Class B
EN 61010 Part 1
Protection Class 2 (front side)
Pollution level 2
over-voltage Category II
Front: double insulation,
Rear side: basic insulation,
+0.6
x 45
11.10 Mechanical Data
Housing:
Panel mount housing
to DIN 43 700, RAL 7021
Dimensions:
96 x 48 x 102 mm
Panel cut-out:
92
Installation depth:
approx. 92 mm incl. terminals
Weight:
approx. 180 g
Protection:
IP 65 (front, device only)
Housing material:
Polycarbonate UL94 V-2
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
EN60068-2-6
30 min in each direction
Shock resistance:
EN60068-2-27
100G / XYZ
3 times in each direction
EN60068-2-29
10G / 6 ms / XYZ
2000 times in each direction
11.11 Connections
Supply voltage and outputs:
Plug-in screw terminal, 8-pin, RM5.00
Core cross-section, max. 2.5 mm²
Signal and control inputs:
Plug-in screw terminal, 9-pin, RM 3.50
Core cross section, max. 1.5 mm²
+0.8
+0.6
x 45
mm