►►13. TROUBLESHOOTING
FUNCTIONING
ANOMALIES
The motor does
not start
The fl ame does
not ignite
The fl ame does
not stay on
Flame goes out
during functioning
kW
kW E
CAUSES
kW R
kW DV
X
X
No voltage
X
X
Power supply cable
faulty/damaged
X
X
Faulty motor
X
Incorrect connection
of the room
thermostat
X
X
Gas cylinder empty
X
X
Regulator safety
valve blocked
X
X
Gas cylinder cock
closed
X
X
Faulty ignition circuit After-sales assistance
X
Ineffi cient earthing
X
Gas button not
pressed for long
enough
X
X
Faulty generator
X
X
Insuffi cient gas
supply
X
X
No gasifi cation of the
fuel
X
X
Appliance
overheating
X
X
Faulty generator
SOLUTIONS
1°Check the mains
system
2°After-sales
assistance
After-sales assistance
After-sales assistance
Connect the room
thermostat correctly
Replace the gas
cylinder (Par. 4)
1°Press the regulator
gas release button
(Fig. 13)
2°After-sales
assistance
Open the gas cylinder
cock (Fig. 12)
Check your system is
earthed correctly
Press the gas button
for longer (Par. 6.1.4.)
After-sales assistance
1°Replace the gas
cylinder (Par. 4)
2°After-sales
assistance
Use gas cylinders with
suitable capacity (Par.
4)
1°Clean the air vent
(rear side)
2°After-sales
assistance
After-sales assistance
IT
GB
DE
ES
FR
NL
PT
DK
FI
NO
SE
PL
RU
CZ
HU
SI
TR
HR
LT
LV
EE
RO
SK
BG
GR
CN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Blp 14 kwBlp 15 kwRblp 26 kwBlp33 kwBlp 53 kwBlp 73 kw ... Afficher tout

Table des Matières