►►8. HEAT CAPACITY
GB
REGULATION
Depending on the type of generator, the
DE
appliance heat capacity can be regulated.
ES
The heat capacity can be regulated by
acting on the knob positioned on the
FR
base of the generator (Fig. 22) or on
the pressure regulator installed on the
NL
gas cylinder (Fig. 23), depending on the
PT
model.
DK
►►9. SWITCH-OFF FOR MANUAL
MODELS (... kW / ... kW R / ... kW
FI
DV)
NO
►9.1.Close the gas cylinder (Fig. 24).
►9.2.Leave the fan to cool for about 60
SE
s, in order to prevent internal damage
PL
due to overheating (generator internal
cooling).
RU
►9.3.Take the "O/I" switch to position "O"
(Fig. 25).
CZ
►9.4.Disconnect the generator from the
HU
mains electricity (Fig. 26).
►9.5.Disconnect the generator from the
SI
gas supply pipe (Fig. 27-28-29).
TR
►►10. SWITCH-OFF FOR
HR
ELECTRONIC MODELS (... kW E)
►10.1.Take the "O/I" switch to position
LT
"O" (Fig. 25). The fl ame goes out and the
LV
generator performs the post-ventilation
phase. Wait for the cycle to be completed
EE
in order to prevent internal damage due
to overheating (the phase is automatic
RO
and can last 50 s÷5 min depending on
SK
the internal/external temperature at the
generator).
BG
►10.2.Close the gas cylinder (Fig. 24).
►10.3.Disconnect the generator from
GR
the mains electricity (Fig. 26).
CN
►10.4.Disconnect the generator from
the gas supply pipe (Fig. 27-28-29).
N.B.: do not disconnect the generator
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.
►►11. CLEANING AND
MAINTENANCE
Have the after-sales assistance check
correct functioning of the generator at
least once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
►11.1.Before
starting
maintenance, care and repairs of the
appliance,
carry
sequence [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... kW / ... kW R /
... kW DV)" or "10. SWITCH-OFF FOR
ELECTRONIC MODELS (... kW E)"].
►11.2.Cleaning only concerns the air
vent (rear side) of the generator.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.
►►12. ROOM THERMOSTAT
CONNECTION (... kW E)
(optional)
Remove the plug connected to the
appliance
and
thermostat (optional) (Fig. 30).
See wiring diagram (... kW E).
any
type
out
the
switch-off
connect
the
room
of