Technical Data
Nominal voltage
Rated power
Max. power
Max. current of connected tools
Degree of protection
Dust category
Air flow (at the fan)
Air flow (at the hose)
Negative pressure (at the fan)
Negative pressure (at the hose)
Sound pressure level (L
Net weight
Dimensions (L x W x H)
Troubleshooting
Problem
Reduced suction
Cleaner doesn't start
Cleaner doesn't start along
with connected tool, although
in A or RA mode
PE collection bag sucked
against the filter
Dust in container after usage
of fleece filter bag
88
EN
)
pA
Cause
filter contaminated
Filter bag full
Container full
Nozzle, pipes or hose blocked
Mains plug not plugged in
Mains power missing
Mains cable defective
Cover is not entirely closed
Container is full
Mode selector in position 0
or in position A or RA without
connected and running tool
Tool is not connected to outlet
socket of cleaner
Solenoid valve defective
Rotary slide inside container is
set to CLOSE
Rotary slide inside container is
set to OPEN
220V – 240V DC, 50/60 Hz
1400 W
1600 W
10 A
IP24
M
75 l/s
45 l/s
280 hPa/MG
245 hPa/MG
≤ 70 dB(A)
12.1 kg
53 x 40 x 56 cm
Solution
Clean
Change
Empty
Clean
Plug in
Check power supply
Replace cable
Close cover
Switch off, remove water from
container, switch on again
Turn selector to I
Connect tool to outlet socket
of cleaner
Contact customer service
Set the rotary slide to OPEN for
PE collection bags.
Set the rotary slide to CLOSE
for fleece filter bags.