Programming and addressing
When programming and addressing SimpleHome automation devices, you will
need SimpleProg software (Version 4.4 or higher), which can be downloaded
from the website pro.comelitgroup.com
For further information regarding programming and functions, please refer to
the SimpleProg manual on the website pro.comelitgroup.com, or scan the QR
code:
Reset procedure
Restart with default network parameters
The restart with default parameters function is used to restart the product with the default
network parameters while keeping the remaining settings unaltered.
√ DIP-switches in default position (OFF)
1. Switch off the power supply to the device
2. Set DIP1 to ON
3. Restore the device power supply
4. Wait for approximately 20-40 sec., until the LEDs flash slowly and alternately
(1 sec. red / 1 sec. green)
5. Set all DIP-switches back to OFF
» The green LED will flash for 5 seconds
» The device will start up with the default network settings applied
6. The next time the device is restarted, the saved parameters will be restored
Restore factory settings
This procedure is used to restore the factory settings of all parameters (ViP address and network
parameters).
√ DIP-switches in default positions (OFF):
1. Switch off the power supply to the device
2. Set all the DIP-switches to ON
3. Restore the device power supply
4. Wait for approximately 20-40 sec., until the LEDs start flashing rapidly and alternately
(0.1 sec. red / 0.1 sec. green)
5. Set all DIP-switches back to OFF
» The red LED will flash for 5 seconds
» The device will restore all parameters to the factory settings and restart in the normal
way
OFF
1
2
OFF
1
2
OFF
1
2
OFF
1
2
OFF
1
2
OFF
1
2
7