OPERATING
GB
FIG. 1
Riduttore di Tensione Switching
Switching Voltage Reducer
5 cm
Abaisseur de Tension Switching
Switching Abspanner
Reductor de Voltaje Switching
VRS 10
ELECTRICAL WIRING
The equipment is to be wired up as shown in figure 1. Always check the input and output termi-
nals for correct polarity.
The electrical wiring is to be done in compliance with local electrical codes.
WARNING: before connecting the batteries, always check the battery cables for correct po-
larity. Remember that wrong polarity may seriously damage the voltage reducer even if the
protected by a fuse.
WARNING: before connecting or disconnecting the cables from the voltage limiter termi-
nals, make sure they are not live.
WARNING: the use of inadequate size cables and the incorrect connection of the terminals
or the electrical joints may result in dangerous overheating of the connecting terminals or
cables.
10
5 cm
I
10
V in +24 Vdc
8
GND
t
V out +13,5 Vdc
5 cm
BATTERY
24 V
5 cm
EQUIPMENT
12 V