ENGLISH
WATER CONNECTION
3/4"
300kPa
3/4"
A
B
C
D
Water inlet hose Fig 9
The water used should have the following properties:
Recommended filters:
A) Fine filter.
If the water contains impurities such as sand, iron particles or floating
substances, we recommend the use of a fine filter at the water input.
B) Activated carbon filter.
If the water has a high chlorine content over 0.2 mg/l (ppm) (this information can
be obtained from the relevant water board), an activated carbon filter should be
installed.
C) Installation of osmosis recirculation.
When the chloride concentration is above 150 mg/l (ppm) (this information can
be obtained from the relevant water board), an osmosis recirculation installation
should be mounted. In this case, please remember that the minimum
conductivity value is 400 µS/cm.
D) Water descaling:
For water with a high level of limescale (without chloride load) the water should
be treated. Systems: H+. Interchange of ions or Kleensteam. We strongly
advise against the use of sodium exchangers (normally used in dish washers)
due to the formation of sodium sediment and the delay in boiling with common
salt.
We recommend the manufacturer, Britta, for the selection of filter systems (A, B,
C, D).
Warnin
Before connection, look at the label that shows which is the water inlet.
:
INSTALLATION MANUAL ADVANCE PLUS
1
R3/4"
Manguera entrada agua
PH 6.5÷7.5
Chlorides < 150mg/litre
Chlorine concentration 0.2÷0.5 mg/litre
Conductivity 400÷2000 µS
Water impurities Ø < 0.08 mm
Water hardness 5-10ºF
Only connect drinking water to the appliance.
Connect the appliance to the mains water
supply at point 1 (Fig9) using the hose
supplied.
The pressure of the incoming water should
be between 200 and 400 kPa (2-4 kg/mm
We recommend 250 kPa.