7.2 Operation Function
DESCRIPTION
1
Plunger Bracket
2
Cartridge Holder
3
Guide Block
4
Air Plunger Inlet
5
Pressure Relief valve
Drive Spindle with
6
Injection Rod
7
Start Buttons (Green)
8
Control Buttons
9
Air Regulator
Emergency Stop
10
button (Red)
11
LCD Display
Protective (Safety)
12
Cover
13
Plunger Disk
14
Fluid Level Sensor
Holds plunger assembly when not in use
Holds cartridge kit
Operates with the plunger assembly and guide block
to drive the cartridge up and down for mixing
Operates with the plunger assembly and cartridge
holder to drive the cartridge up and down for mixing
Provides air to plunger
Relief plunger pressure when door is opened
Rotates mix rods during mix cycle
Injects the hardener into the resin
Starts the unit
Press green buttons simultaneously to start
Input buttons (see Fig. 4.0 and Fig. 5.0)
Regulates the air pressure to the unit
Stops the Unit in an Emergency
Press to Engage
"E-Stop!'' will be displayed,
To reset, rotate the E-Stop knob a quarter turn
clockwise
Displays unit status, operation and error messages.
Protects operators when machine is in use
Part of Plunger Assembly
Senses the fluid level at the top of the cartridge
9