7. Measuring AC Voltages
The output wave of the AC inverter is a MODIFIED SINEWAVE. An AUTHENTIC RMS VOLT METER is required to
measure the AC output voltage. Using any other type of voltage measuring device will result in an AC voltage
reading that is up to 20 to 30V lower than the rated value. Only an authentic RMS voltmeter provides an accurate
reading.

8. Technical Specifications

The following chart contains all VELLEMAN square wave inverters. Every type is available in a 12V or a 24V version.
The suffix x or xx stands for the plug type of the output.
S = German type Schuko plug
B = French type Schuko plug
DC Input Voltage
Output Voltage
Battery-Low alarm
Battery-Low Shutdown
Auto restart
Short-circuit Protection
No-Load Current
Overheating Protection
Protection
Dimensions
Weight
AC Output Voltage
Frequency
For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.
PSI SERIES_v2
PSI150
DC 10V – 15V (12V) / DC 20V – 30V (24V)
150W
10.5VDC +/- 0.5VDC (12V) / 21VDC +/- 1VDC (24V)
10VDC +/- 0.5VDC (12V) / 20VDC +/- 1VDC (24V)
The power inverter being shut off through e.g. the short-circuit protection does not
need to be switched on manually; it will restart automatically.
250mA (12V)
Overload, high temperature, short-circuit, reverse polarity protection
160 x 104 x 58
730g
PSI300
300W
Yes, with auto restart
0.3A (12V)
55°C +/- 5°C
180 x 104 x 59
830g
230VAC +/- 5%
50Hz +/- 1Hz
- 6 -
PSI600
600W
0.4A (12V)
210 x 91 x 58
1100g
HQPOWER