Psm3000 Connections (Rbmp1) Ssà Digital Inputs - CAME PS Série Manuel D'installation

Systeme controle parkings
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

20
PSM3000 connections (RBMP1) ßà digital inputs
Digital inputs are use to connect up the magnetic coils which instantly provide a count of the number of vehicles in the parking facility,
they command the traffi c lights independently of the PSE/PSU3000 entrance and exit units. They are often used in multi-level parking,
or ones with one entrance and one exit. The coils may be used to obtain an exact count of the number of vehicles on each level, which
provides and exact number of free spaces on each parking level.
PSU3000
PSC3000
PSE3000
RBMP1
PS BARCODE -
Example of multi-level parking with vehicle count coils on each level
Exit magnetic
coil
PSM3000
Traffi c light
Entrance
magnetic coil
Method to connect the extra RBMP1/PSIO coils, to count the exact
number of cars at each fl oor. A tw-channel detector device such as th
e SMA2 is preferable, used in mono-directional mode. Also see product
literature.
Hardware and wiring
Traffi c light
Traffi c light
Entrance
magnetic coil
Traffi c light