LaserLiner CAT III Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Technical data
Function
Max. input voltage
DC voltage
AC voltage
DC current
Batteries
Diode test / resistance
Resistance
Input sensitivity
Polarity
LCD
Fuse
Protection class
Overvoltage category
Pollution degree
Degree of protection
Operating conditions
Storage conditions
Power supply
Dimensions
Weight (incl. battery)
Test standards
Subject to technical alterations. 09.2017
22
EN
Range
300 V AC / DC
200 mV
2,000 mV
20 V
200 V
300 V
200 V
300 V
2,000 μA
20 mA
200 mA
10 A
1.5 V round cells / AA, AAA, C, D
1.2 V round cells (NiMH) / AA, AAA, C, D
9.0 V flat cells / E-block
8.4 V flat cells (NiMH) / E-block
Test voltage max. 3.2 V
200 Ω
2,000 Ω
20 kΩ
200 kΩ
2,000 kΩ
1 MΩ (V DC) / 500 kΩ (V AC)
Sign for negative polarity
(3 1/2 segments, 1,999 digits)
F 250 mA / 300 V, F 10 A / 300 V,
(Ø 5 x 20 mm)
II, double insulation
CAT III - 300V (non-condensing)
Pollution degree 2
2
IP 20
0°C ... 40°C , Max. humidity 75% rH, no
condensation, Max. working altitude 2000 m
above sea level
-10°C ... 50°C, Max. humidity 80% rH
1 x 9 V battery (NEDA 1604, IEC 6F22)
77 x 139 x 28 mm
204 g
EN61010-1, EN61010-2-030,
EN61010-2-033, EN61326-1, EN61326-2-2
Accuracy
± (0.5% rdg + 5 digits)
± (0.8% rdg + 5 digits)
± (1.0% rdg + 5 digits)
± (1.2% rdg + 10 digits)
± (1.0% rdg + 5 digits)
± (1.2% rdg + 5 digits)
± (2.0% rdg + 5 digits)
± (1.0% rdg + 5 digits)
± (0.8% rdg + 5 digits)
± (1.2% rdg + 5 digits)

Publicité

Table des Matières
loading

Table des Matières