ERROR MESSAGES

*Error
Reason
E1
Coil Sensor-Error
E2
Moisture Sensor-Error
E3
Temperature Sensor-Error
E4
Hot and Cold System-Error
E5
Room Temperature too high
* If an error occurs, display will show the respective code.

ERROR ANALYSIS

Error
Dehumidifier does
not work.
Bad dehumidification
performance
High noise level
Reason
1. Device has no power.
2. Mains plug is not plugged in
properly.
3. Display shows error code E4.
1. Air in- or outlet is covered.
2. Room is not closed.
Low moisture and temperature.
1. Device was not put on even
ground.
2. Air in- or outlet is covered.
EN
Solution
Exchange the coil sensor.
Exchange the moisture sensor.
Exchange the temperature sensor.
Have the dehumidifier checked /
repaired by a specialist.
Lower the room temperature and
dehumidifier will restart
automatically.
Solution
1. Turn on the power supply.
2. Connect the mains plug properly.
3. Empty the water collection
container.
1. Uncover Air in- and outlet.
2. Close all doors and windows.
3. The lower the room temperature
the worse the dehumidifi cation
performance.
1. Position the device on even
ground.
2. Uncover Air in- and outlet.