REFERENCE
ORDERING CODE
2016 0714
2016 0734
2016 0716
2016 0736
2016 0724
2016 0744
2016 0726
2016 0746
2016 0754
2016 0774
2016 0756
2015 0776
AFFICHAGE
Type d'affichage: bargraphe, LEDs rouges
N° segment (led): 30
ENTREE 0...Un
N° segment (led): 29 + 1 signalisation appareil alimenté
ENTREE 1...5 - 2...10V
N° segment (led): 28 + 1 signalisation appareil alimenté + 1 signalisation 1 - 2V
Dimensions du segment: 2x5mm
Longueur de l'échelle: 75mm
Disposition de la barre: horizontale ou verticale
Graduation de l'échelle: 0...100% - 100...0...100%
Indication du dépassement: clignotement des 10 derniers segments
Précision: ± 1 segment
Temps de réponse: ≤ 100ms
ENTREE
Raccordement: direct
Courant nominal Un: 5 - 10 - 1...5 - 2...10V
Etendue de mesure: 0...Un ou –Un...0...Un
Impédance d'entrée: ≥ 10M Ω (Un ≤ 2V)
≥ 300k Ω (Un > 2V)
Surcharge permanente: 1,2Un
Surcharge instantanée : 2Un/5s
ALIMENTATION AUXILIAIRE
Valeur nominale: 18...36Vcc
Protection contre l'inversion de polarité
Autoconsommation: ≤ 2W
ISOLEMENT
Catérogie de l'installation: III
Degré de pollution: 2
Tension d'essai 2kV valeur efficace 50Hz/1 min
Circuits considérés: mesure, alimentation
Tension d'essai 4kV valeur efficace 50Hz/1 min
Circuits considérés: tous les circuits et la masse
COMPATIBILITÉ ELECTROMAGNETIQUE
Test d'émission selon EN/IEC 61326-1
Test d'immunité selon EN/IEC 61326-1
ENTREE
DISPOSITION BARRE
INPUT
BAR POSITION
0...5V
0...10V
0...5V
0...10V
5...0...5V
10...0...10V
5...0...5V
10...0...10V
1...5V
2...10V
1...5V
2...10V
(EN/IEC 61010-1)
Vertical
Vertical
Horizontal
orizontal
Vertical
Vertical
100...0...100%
Horizontal
orizontal
Vertical
Vertical
Horizontal
orizontal
DISPLAY
Type of display: bargraph, red LED's
N° of segments (led): 30
INPUT 0...Un
N° of segments (led): 29 + 1 to signal fed meter
INGRESSO 1...5 - 2...10V
N° of segments (led): 28 + 1 to signal fed meter + 1 to signal 1 - 2V
Segment size: 2x5mm
Scale lenght: 75mm
Bar position: horizontal or vertical
Scale marking: 0...100% - 100...0...100%
Overrange indication: blinking of last 10 segments
Accuracy: ± 1 segment
Response time: 100ms
INPUT
Connection: direct
Rated current Un: 5 - 10 - 1...5 - 2...10V
Measuring range: 0...Un opp. –Un...0...Un
Input impedance: ≥ 10M Ω (Un 2V)
≥ 300k Ω (Un > 2V)
Continuous overload: 1,2Un
Instantaneous overload: 2Un/5s
AUXILIARY SUPPLY
Rated value: 18...36Vdc
Protected against incorrect polarity
Rated burden: 2W
INSULATION
Installation category: III
Pollution degree: 2
A.C. voltage test 2kV r.m.s. 50Hz/1 min
Considered circuits: measure, supply
A.C. voltage test 4kV r.m.s. 50Hz/1 min
Considered circuits: all circuits and earth
ELECTROMAGNETIC COMPATIBILITY
Emission tests according to EN/IEC 61326-1
Immunity tests according to EN/IEC 61326-1
ECHELLE
ALIM. AUX.
SCALE
AUX. SUPPLY
0...100%
18...36V
0...100%
(EN/IEC 61010-1)