Display
3 ½ digits (2,000 counts) LCD
AC Current Bandwidth
50/60Hz (AAC)
AC Voltage Bandwidth
50/400Hz (VAC)
Operating Temperature
-10°C ~ 50°C (14°F ~ 122°F)
Storage Temperature
-30°C ~ 60°C (-14°F ~ 140°F)
Relative Humidity
90% (0°C ~ 30°C or 32°F ~ 86°F)
75% (30°C ~ 40°C or 86°F ~ 104°F)
45% (40°C ~ 50°C or 104°F ~ 122°F)
Altitude
operating: 3,000m
storage: 10,000m
Over-voltage
category III 600V
Auto Power-Off
after approx. 15 min
Power Supply
2 x 1.5V AAA batteries (incl.)
Dimensions
205 x 70 x 37mm
Weight
210g with battery
Accessories
manual, test leads, batteries, carrying bag
Function
Range
2.000 AAC
20.00 AAC
AC Current
200.0 AAC
400 AAC
200.0 mVDC
2.000 VDC
DC Voltage
20.00 VDC
200.0 VDC
600 VDC
200.0 mVAC
2.000 VAC
AC Voltage
20.00 VAC
200.0 VAC
600 VAC
200.0Ω
2.000kΩ
20.00kΩ
Resistance
200.0kΩ
2.000MΩ
20.00MΩ
6. Operation
Read and understand all warning and precaution statements listed in the safety
section of this manual before operating. Set the function selector switch in the
OFF position when the meter is not in use.
• AC Current Measurement
Ensure that the test leads are disconnected from the
meter before making current measurements.
o Set the function switch to an A range. If the
measurement range is not known, select the
highest range and move to the lower range if
necessary.
o Press the lever to open the jaw. Fully enclose the conductor to be measured.
o Read the displayed value.
ECM330
Accuracy
± (2.5% of rdg + 10 digits)
± (2.5% of rdg + 4 digits)
± (3.0% of rdg + 4 digits)
± (0.5% of rdg + 510 digits)
± (1.2% of rdg + 3 digits)
± (1.5% of rdg + 3 digits)
± (1.5% of rdg + 30 digits)
± (1.5% of rdg + 3 digits)
± (2.0% of rdg + 4 digits)
± (1.0% of rdg + 4 digits)
± (1.5% of rdg + 2 digits)
± (2.0% of rdg + 3 digits)
± (3.0% of rdg + 5 digits)