Parameters Menu Table - Illinois Tool Works Stero SU-L Mode D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PARAMETERS MENU TABLE

Parameter
Name
Detergent
Enables or disables the detergent pump.
Pump
Rinse Aid
Enables or disables the rinse aid pump.
Pump
Wash Cycle
Sets the cycle duration.
Enables or disables a visual alert on the display that indi-
cates that the Final Rinse water temperature is below the
required minimum of 180°F (82°C). When enabled, a mes-
sage will display notifying the user of this condition after
Low Temp
three consecutive cycles do not reach the required final rinse
Alarms
temperature. However, machine operation will not change
(SU-H
and ware will continue to wash as expected. After the tem-
Model Only)
perature increases past the minimum, the message stops.
When disabled, there will be no extra message indicating a
low temperature event; however, the temperature display
will still show the current Final Rinse water temperature.
Delime
Enables or disables the alert to delime option.
Temperature
Sets the display units to either Fahrenheit or Celcius.
Units
Add
Enables or disables an audible alert if chemical is not being
Chemical
detected.
Alert
End Cycle
Enables or disables an audible alert at the end of a cycle.
Audio Alert
Language
Sets the language on the display to either English or French.
Press ENT to exit the Parameters Menu and return to the
Exit Menu
Manager Menu. Any settings that were changed are saved.
STERO UNDERCOUNTER DISHWASHER & GLASSWASHER
Description
Possible
Default
Values
Value
Disabled or
Enabled
Enabled
Disabled or
Enabled
Enabled
Light, Normal,
Normal
or Heavy
Disabled or
Disabled
Enabled
Disabled or
Enabled
Enabled
Fahrenheit or
Fahrenheit
Celsius
Disabled,
Visual, or
Audio and
Audio and
Visual
Visual
Disabled or
Disabled
Enabled
English (US) or
French
English (US)
(Canada)
| 15

Publicité

Chapitres

Table des Matières
loading

Table des Matières