Installation Instructions:
DO NOT INSTALL DURING ACTIVE
STORM CONDITIONS.
This device can be used indoor (FSPHONE), or outdoor when installed in weatherproof
housing(FSPHONE4X). Failure to follow installation instructions can result in personal
injury and/or equipment damage not covered by warranty.
FSPHONE – For indoor use:
▪
FSPHONE protects 2 pairs (1 pair per protector module) and is intended for
indoor use only, without additional housing.
▪
Attach securely to mounting surface.
▪
Install ground wire, and if applicable, service shield, under top center nut of
mounting bracket and tighten nut securely.
▪
Connect one pair (tip and ring) under the bottom nut on each protector
module, tip on one post, ring on the other.
▪
Connect the customer wiring, tip and ring, under the top nut on the same
protector module (protector is wired in parallel)
▪
Check all wiring for loose connections and shorting or broken wires.
FSPHONE4X – For outdoor use:
▪
Mount weatherproof housing securely to flat surface.
▪
Conductors will enter and exit from the flexible grommet located at bottom of
enclosure.
▪
Follow instruction above for FSPHONE connections.
▪
Secure enclosure with tie wrap or similar locking device.
▪
The FSPHONE4X is a Parallel Device.
Telco Side Cable
Terminate Between
Washers
Ground Clip
Customer Side
Cable
Terminate Between
washers