Safety Safety Symbol and Signal Word Review When you see these Safety Symbols and Signal Words on MECHANICAL the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them.
System Specifi cations ........... 8 Wire Specifi cations ............9 PRE-INSTALL Internet Service ............10 Phone Provider ............10 Setup a LiftMaster Cloud Account ....... 10 INSTALL Remove Knockouts ............. 11 Mount the CAPXL ............12 Install Antennas............13 Install the Ground............14 Connect Power ............
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Power/Internet Board Overview Speaker Audio Postal Lock Sensor Board Display Backlight Display (Touch) Dip Switches Power Connection (Switch #1 is used to for Control Board toggle Admin Mode) LOOP BOARD Door Board 2 RADIO ANTENNA POWER Door Board 1 ETHERNET...
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Door Board Overview The CAPXL has a combination of access control inputs/outputs on the Door Boards that work in conjunction to control up to 4 access points. DOOR BOARD 1 DOOR BOARD 2 Door 1 Door 2 Door 3 Door 4...
Security+ 2.0 ® Wireless Communication to Gate Operator Up to 750 feet (228.6 m), Open Air/Line-of-Sight (range will vary depending on obstructions), Compatible with LiftMaster Security+ 2.0 ® gate operators NOTE: Wi-Fi and wireless ranges were not evaluated by UL.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Wire Specifi cations Use this chart to pull wires in preparation of your installation. Check the national and local building codes BEFORE installation. DESCRIPTION OF WIRE RUN WIRE SPECIFICATION MAXIMUM RUN DISTANCE Power Wire, secondary DC output 2-Conductor 14 AWG Up to 300 feet (91.4 m) 2-Conductor 16 AWG...
A subscription with a SIP provider is required for the CAPXL to make phone calls. Phone.com is the preferred SIP provider and the only provider LiftMaster certifi es calling performance. Sign up through LiftMaster Cloud after a CAPXL is added to a Facility.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Remove Knockouts 1. Turn the key clockwise to unlock the CAPXL. To prevent damage to the CAPXL from moisture or water: • DO NOT install during rain. Internal components MUST be 2. Open the door and lay the CAPXL face down on kept free from of water and moisture.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Mount CAPXL Make sure the CAPXL is properly sealed to 1. Attach the goose-neck gasket (provided) if mounting to a goose-neck. prevent damage to the CAPXL from moisture. 2. Mount the CAPXL securely to a fl at surface or pedestal with appropriate hardware taking care to route wiring through appropriate knockouts.
CAPXL. Optional antenna cable kits are available for remote antenna mounting (refer to accessories). ® Security+ 2.0 Radio Antenna (if applicable) ® Used with LiftMaster Passport Security+ 2.0 and wireless communication with LiftMaster UL325 2016 compliant gate operators. Security+ 2.0 ® Radio Antenna 1. Remove 3/8" knockout on the side or back of the CAPXL.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Install the Ground IMPORTANT: An earth ground rod is strongly recommended and should be no To AVOID damaging gas, power or further than 12 feet (3.7 m) from the CAPXL and use a minimum of 12 gauge other underground utility lines, contact underground utility locating wire in most cases.
NOTE: The green LED on the door board will blink and the green LED on the Power/Internet Board will light solid when powered up. The CAPXL will display the LiftMaster logo while booting up. When boot up is complete, the user interface will appear.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Connect Internet Dipswitch #1 on the Power/Internet board ® The CAPXL can connect to the Internet with a wired connection or with Wi-Fi (wireless). Make sure you are in the Admin Mode before you connect to the Internet. If you are not in Admin Mode, fl...
Gate Access (Wired) Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can be wired to Door 1, 2, 3, or 4 on the Door Boards. LiftMaster ® Security+ 2.0 ®...
UL325 2016 gate operators to send open commands, monitor gate position, and send email notifi cations if an error occurs in the operator (email notifi cations are confi gured in LiftMaster Cloud). Up to 8 gate operators can be paired with the CAPXL - one for each primary and auxiliary relay. If using dual gates, program the CAPXL to the primary operator.
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Door Access Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for door access. Door access can be wired to Door 1, 2, 3, or 4 on the Door Boards. WIEGAND RFID ANTENNA NOTE: The length of the unshielded...
Insulate any unused wires from the CAPXL to prevent a short. (Refer to instructions provided with your Reader reader for more information.) Wing Nuts 6. Reconnect power to the CAPXL. 7. Refer to LiftMaster Cloud for programming. Mounting Plate Mounting Holes Cable Hole...
Disconnect power BEFORE making electrical connections. The CAPXL offers a Wiegand output capable of 26 bit transmission of the following data: • Success Call with access granted by the resident. The CAPXL will provide a LiftMaster Cloud specifi ed facility code followed by the Directory Code of the resident that granted access. And/Or •...
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Postal Lock 1. Remove the wing nut and plug. Discard the wing nut and plug. 2. Remove 4 mounting nuts from studs. 3. Install postal lock using 4 nuts from step 2. 4. Cut the factory installed wire tie from the postal lock switch. The postal lock switch is wired from the factory.
LOOPDETLM can be purchased together as a kit (LPEXPKIT). When the loop detects SHADOW Not supported a vehicle the number programmed into the “Quick call” fi eld in LiftMaster Cloud is automatically dialed. AUXILIARY 1. Secure the Loop Detector Board (model LPEXP) to the standoffs in the CAPXL with the provided screws.
Wiring Diagram Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes. The information is for suggested use ONLY. Check your local codes BEFORE installation. orange blue white MICROPHONE 1 - Red black 2 - Orange 3 - Yellow...
** Available in 10 and 100 packs, replace X with 10 or 100 NOTE: A current list of compatible readers and keypads is maintained at LiftMaster.com. If you have a specifi c model of reader or keypad that is not listed on the LiftMaster website, please contact LiftMaster Technical Support to determine compatibility.
Confi guration Sheet Record device information and confi guration settings below. CAPXL Name: NOTE: Any user of the system is subject to the terms outlined in the product EULA. Notes: DEVICE CONFIGURATION: DOOR 1 DOOR/GATE NAME: WIEGAND STATUS INPUTS EOL (Y / N) PRIMARY RELAY AUXILIARY RELAY OUTPUTS...
The CAPXL shall be installed in accordance with Part 1 of the Canadian Electrical Code. Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of LiftMaster. For the most up-to-date information, visit LiftMaster.com.
Warranty LiftMaster (“Seller”) warrants to the fi rst purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase.
LiftMaster Cloud™ Portail d’accès connecté – Haute capacité MANUEL D’INSTALLATION...
Page 30
Sécurité Examen des symboles de sécurité et des mots de signalement MÉCANIQUE Les symboles de sécurité et mots de signalement qui fi gurent sur les pages suivantes avisent le lecteur de la possibilité de blessures graves ou de mort en cas de non-conformité aux avertissements ATTENTION qui les accompagnent.
Page 31
Caractéristiques techniques du câblage ......9 PRÉINSTALLATION Service Internet ............10 Fournisseur de service téléphonique ......10 Confi guration d’un compte LiftMaster Cloud ....10 INSTALLATION Enlever les alvéoles défonçables ......... 11 Monter le CAPXL ............12 Installer les antennes ..........13 Installer la tige de mise à...
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Présentation du CAPXL FENÊTRE DE LA CAMÉRA MICROPHONE ÉCRAN (TACTILE) VERROU EMPLACEMENT DU LECTEUR DE PROXIMITÉ EMPLACEMENT HAUT-PARLEUR DU VERROU POSTAL ANTENNE Wi-Fi ® CARTE DE CAPTEUR ANTENNE RADIO SUPPORT DE MONTAGE DE LA CAMÉRA CARTE D’ALIMENTATION/INTERNET ®...
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Présentation de la carte d’alimentation/Internet Haut-parleur Audio Verrou postal Carte de capteur Rétroéclairage de l’écran Écran (tactile) Commutateur DIP Connexion de (Le commutateur n 1 sert à l’alimentation au basculer en mode d’administration) tableau de commande CARTE DE BOUCLE DE DÉTECTION Carte de porte 2...
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Présentation de la carte de porte Le CAPXL est doté d’une combinaison d’entrées et de sorties de commande d’accès sur les cartes de porte qui fonctionnent conjointement pour commander jusqu’à quatre points d’accès. CARTE DE PORTE 1 CARTE DE PORTE 2 Porte 1 Porte 2...
Communication sans fi l à l’actionneur de Jusqu’à 228,6 m (750 pi), champ libre/visibilité directe (la portée variera selon les barrière obstacles présents), compatible avec les actionneurs de barrière LiftMaster ® Security+ 2.0 REMARQUE : Les portées Wi-Fi et sans fi l n’ont pas été évaluées par l’UL.
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Caractéristiques techniques du câblage Utiliser ce tableau pour tirer les fi ls en préparation de votre installation. Vérifi er les codes de construction nationaux et locaux AVANT l’installation. DESCRIPTION DU FILAGE CARACTÉRISTIQUES TECHNIQUES DISTANCE MAXIMALE DU FILAGE DU CÂBLAGE Fil électrique, sortie c. c.
Phone.com est le fournisseur de protocole SIP de préférence et le seul fournisseur dont LiftMaster certifi e la performance d’appel. S’inscrire par le biais de LiftMaster Cloud après avoir ajouté un CAPXL à une installation. Si un autre fournisseur de protocole SIP est utilisé, les renseignements suivants seront nécessaires.
INTRODUCCIÓN INTRODUCCION PRÉINSTALLATION PREINSTALACIÓN INSTALLATION INSTALACIÓN RÉSEAU CONTROL DE ACCESO CONTRÔLE D'ACCÈS Enlever les alvéoles défonçables Afin de prévenir les dommages au CAPXL causés par l’humidité ou l’eau : 1. Tourner la clé dans le sens des aiguilles d’une • NE PAS procéder à l’installation sous la pluie. Les composants montre pour déverrouiller le CAPLX.
INTRODUCCIÓN INTRODUCCION PRÉINSTALLATION PREINSTALACIÓN INSTALLATION INSTALACIÓN RÉSEAU CONTROL DE ACCESO CONTRÔLE D'ACCÈS Monter le CAPXL FAIRE CECI S’assurer que le CAPXL est adéquatement scellé pour empêcher les dommages causés Fixer le joint à col long (fourni) en cas de montage sur un col de cygne. par l’humidité.
® Antenne radio Security+ 2.0 (s’il y a lieu) Utilisée avec LiftMaster Passport Security+ 2.0 ® et la communication sans fi l avec les actionneurs de barrière LiftMaster 2016 conformes à la norme UL325. Antenne radio Security+ 2.0 ® 1. Enlever l’alvéole défonçable de 3/8 po...
INTRODUCCIÓN INTRODUCCION PRÉINSTALLATION PREINSTALACIÓN INSTALLATION INSTALACIÓN RÉSEAU CONTROL DE ACCESO CONTRÔLE D'ACCÈS Installer la tige de mise à la terre ATTENTION ATTENTION IMPORTANT : Une tige de mise à la terre est fortement recommandée et Pour ÉVITER d’endommager les conduites ne doit pas être située à...
REMARQUE : La DEL verte sur la carte de la porte clignotera et la DEL verte sur la carte d’alimentation/Internet s’allumera en continu au moment de la mise sous tension. Le CAPLX affi chera le logo LiftMaster pendant le démarrage. Une fois le démarrage effectué, l’interface utilisateur s’affi...
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Commutateur DIP Connecter l’appareil à Internet 1 sur la carte d’alimentation/ Internet ® Le CAPXL peut être connecté à Internet par une connexion câblée ou avec Wi-Fi (sans fi l). Vérifi er d’être bien en mode d’administration avant d’établir la connexion à Internet. Si l’appareil n’est pas en mode d’administration, mettre le commutateur DIP n 1 à...
Déconnecter l’alimentation AVANT d’effectuer des connexions électriques. Un exemple de confi guration de câblage pour accès à la barrière est présenté ci-dessous. L’accès à la barrière peut être câblé à la porte 1, 2, 3 ou 4 sur les cartes de porte. Les actionneurs de barrière LiftMaster ®...
(les notifi cations par courriel sont confi gurées dans LiftMaster Cloud). Jusqu’à 8 actionneurs de barrière peuvent être jumelés au CAPXL – un pour chaque relais primaire et auxiliaire.
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Accès à la porte Déconnecter l’alimentation AVANT d’effectuer des connexions électriques. Un exemple de confi guration de câblage pour accès à la porte est présenté ci-dessous. L’accès à la porte peut être câblé à la porte 1, 2, 3 ou 4 sur les cartes de porte. WIEGAND ANTENNE RFID REMARQUE : La longueur des fils non blindés...
CAPXL afi n de prévenir un court-circuit. (Consulter les Lecteur instructions fournies avec le lecteur pour plus d’information.) Écrou à oreilles 6. Reconnecter l’alimentation au CAPXL. 7. Consulter LiftMaster Cloud pour la programmation. Plaque de montage Trous de montage Trou destiné...
Déconnecter l’alimentation AVANT d’effectuer des connexions électriques. Le CAPXL offre une sortie Wiegand à capacité de transmission de 26 bits des données suivantes : • Appel réussi avec accès accordé par le résident. Le CAPXL fournira un code d’installation précisé par LiftMaster Cloud suivi du code de répertoire du résident qui a accordé l’accès. et/ou •...
INTRODUCCION PRÉINSTALLATION INSTALLATION RÉSEAU CONTRÔLE D'ACCÈS Verrou postal 1. Enlever l’écrou à oreilles et le bouchon. Jeter l’écrou à oreilles et le bouchon. 2. Enlever 4 écrous de montage des goujons. 3. Installer le verrou postal avec les 4 vis de l’étape 2. 4.
LPEXP et la boucle LOOPDETLM peuvent être achetées ensemble dans une trousse INTERRUPTION Non pris en charge (LPEXPKIT). Lorsque la boucle détecte un véhicule, le numéro programmé dans le champ « Appel rapide » (Quick call) dans LiftMaster Cloud est automatiquement composé. PASSAGE Non pris en charge AUXILIAIRE...
Schéma de câblage Non responsable des conflits entre l’information indiquée dans le schéma de câblage et les exigences des codes du bâtiment de votre région. Cette information est fournie UNIQUEMENT à titre de suggestion. Consulter les codes de votre région AVANT l’installation. orange bleu blanc...
** Offertes en paquets de 10 et 100, remplacer le X par 10 ou 100 REMARQUE : Une liste actuelle des lecteurs et claviers compatibles est maintenue à LiftMaster.com. Si votre modèle de lecteur ou de clavier particulier ne fi gure pas sur le site Web de LiftMaster, contacter l’assistance technique de LiftMaster pour en déterminer la compatibilité.
Fiche de confi guration Noter l’information sur l’appareil et les paramètres de confi guration ci-dessous. Nom du CAPXL : REMARQUE : Tout utilisateur de ce système est soumis aux dispositions de l’accord d’utilisation du produit. Remarques : CONFIGURATION DU DISPOSITIF : PORTE 1 NOM DE LA PORTE/BARRIÈRE : WIEGAND Demande de sortie (REX) ÉTAT...
Page 55
Le CAPXL doit être installé conformément à la partie 1 du code canadien de l’électricité. Déni de responsabilité et restrictions concernant la documentation L’information contenue dans ce document peut être modifi ée sans préavis et ne constitue pas un engagement de la part de LiftMaster. Pour obtenir l’information la plus à jour, visiter www.LiftMaster.com.
Garantie LiftMaster (le « vendeur ») garantit à l’acheteur initial de ce produit pour la structure dans laquelle ce produit est originalement installé que le produit est exempt de tout défaut matériel ou de fabrication pour une période de deux (2) ans à compter de la date d’achat.