Télécharger Imprimer la page

effeff 5512-13 Notice D'installation page 9

Publicité

Les langues disponibles

Les langues disponibles

Connecting diagram for models 5522, 5523, 5525 und 5526
ON
1
2
3
4
1 2 3 4 5 6 7 8
Electro power bolt
5522, 5523,
5525, 5526
illustration 2: Connecting diagram for motorized power bolt
Terminal assignment:
1-8 terminals for motorized power bolt.
S 5 Possibility to connect a switching contact (e. g. timer). The door is locked when
contact S5 is closed. If contact S5 is closed the door can be momentarily unlocked
by operating push button S7. If contact S5 is not connected or open the door is
unlocked. In this case the door can be permanently unlocked or locked manually by
means of push buttons S7 and S8. Triggering must be effected by means of
potential-free contacts.
S 6 Attention: Indispensable
A door contact which must be installed in the door frame (cone contact). This
contact is used for monitoring the state of the door (open/closed). Throwing of the
bolt and consequently locking is only possible when the door is closed
(S6 closed).
S 7 Push button for manual momentary unlocking:
Triggering must be effected by means of a potential-free contact.
S 8 Push button for manual locking:
Triggering must be effected by means of a potential-free contact.
Possibility to connect an external monitoring display system:
Terminal 17 conducts 12 V when the door is closed, terminal 18 conducts 12 V
when the door is open. The maximum capacity of the outputs is 100 mA.
Possibility to connect a power supply unit (terminals 19 and 20):
The voltage range to be supplied by the power supply unit is 12-16 V AC/DC and
the unit must provide a capacity of 1.5 A in case motorized power bolt models
5522, 5523 are used. We recommend model 1001-121.
Possibility to connect power supply unit (terminals 21 and 22):
The power supply unit must supply 12 V stabilized DC and provide a capacity of
1.5 A. Positive pole to terminal 21, negative pole to terminal 22.
To
and
Instructions on wiring and installation must be observed precisecly! Otherwise guarantee will become invalid.
Control Device for Motorized Power bolts 5512-13
9 10
S5
S6
: Only one power supply unit must be connected!
13 14
15 16
11 12
S7
S8
17 18
19 20
21 22
gn
rt
power supply
D00213-A0000301