22
K44 Duo Installation & User manual
Enter duress code
This is how to activate the alarm output when
forced to open the door under threat:
Enter the usual entrance code, only add 1 to the
last digit in the code.
Example 1: If the entrance code is 1234, enter
1235 instead.
Example 2: If the code is 1239, enter 1230 in-
stead.
When a duress code is entered, the door will open
at the same time as the duress output is activated.
It will remain activated until reset by somebody
entering programming mode.
K44 Duo Installation & User manual
Technical data
Power supply:
Power consumption:
Maximum load over
the relay contacts:
Dimensions
(HxWxD) mm:
Suitable height:
If needed, complete the installation with
flush mounting kit BB3.
23
8-24 V AC, 10-35 V DC
75 mA.
2 A 28 V DC
140x80x40
1200-1400 mm from
ground to bottom edge.