10 MAINTENANCE

10.1 Errors

The errors with different actions for Self-service are listed below. The others are the same.
ERROR
DESCRIPTION
HEATING FAULT
E6
UNBALANCED LOAD
E9
CAUSE AND ACTION
The machine detects that, in spite of activating the heating output, the
water temperature has not increased within 30 minutes
It is possible to cancel this error. In this case, instead of triggering an error, the
machine will continue running as if the temperature had been reached.
A warning is displayed but the machine does not stop. It continues with the
programme but the warning remains until the programme ends and the door is
opened.
In the final spin distribution, the input "Unbalanced load switch" is activated 5
times.
An error is not triggered and the machine spins at low speed. The programme
ends normally without warnings.
.