To verify the controller type is set correctly:
1.
Apply power to the power pack.
2.
Wait for the start-up sequence to complete.
3.
Press and hold the OUTPUT button for approximately four (4) seconds. After four (4) seconds, a controller type
will be displayed on the screen.
4.
Verify that the JANDY L/M controller type appears on the display. If the contoller type is not set to JANDY L/M,
keep the OUTPUT button pressed to toggle through the list of contollers. Each controller will be displayed on the
screen for two (2) seconds. Release the OUTPUT button when JANDY L/M appears on the display.
3.6.2 Wiring to the AquaLink
1.
Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker.
2.
Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals
(see Figure 24).
NOTE: Be careful not to pull the ribbon cable that is connected to the Power Supply and the Cover.
3.
Remove the white cap covering the comm hole (see Figure 24).
4.
Thread the controller cable through the hole. A grommet may be necessary depending on the size of the cable
being used.
5.
Attach a cable tie to the controller cable as shown (see Figure 24).
6.
The Jandy
AquaLink RS or PDA and power pack use a four (4) wire connection to communicate and can be
®
wired up to 500 ft (152.4 m) apart. Any outdoor rated four conductor cable, minimum 22 AWG (0.33 mm
be used. Locate the appropriate screw terminals on the circuit board and wire the power pack to the AquaLink RS
or PDA red 4-pin terminal bar (see Figure 25).
NOTE The screw terminals on the AquaLink RS or PDA are removable to aid in installation.
Comm Hole
Figure 24.
Accessing and Wiring to the Power PCB
RS Control System or PDA
®
Red, 4-Pin
Terminal Bar
Cable Tie
Figure 25.
4 3 2 1
OPTIONAL
Jandy
Power Center
Communication Wiring between Power
Pack and AquaLink RS Control System or
PDA Network
Page 15
2
), can
Power Pack
GRN
YEL
BLK
RED