Section 3. Installation Instructions; Materials And Tools; Installation Requirements - Zodiac Pool Systems Jandy AquaPure Ei Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 10
Section 3.
Installation Instructions
FOR YOUR SAFETY: This product must be serviced by a professional pool/spa service technician. The
procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in
property damage, serious injury, or death. Improper installation and/or operation will void the warranty.
EQUIPMENT UNDER PRESSURE: Always turn pump off prior to installing or servicing the Jandy
Ei
chlorine generating device. Your pump/fi lter system is operated under pressure and the pressure must be
TM
released before you begin work. Please see your pump/fi lter owner's manual for further instructions.
Before you begin your installation, please check that you have the right tools and a suitable location to install the
power pack and cell. Please ensure that you have read and understood the Important Safety Instructions section.

3.1 Materials and Tools

Installation Materials Furnished
• Pipe Spacer - for 1½ in. (40 mm) pipe
• Bonding Wire
• Hole Saw
• Screw Set (includes wall plugs)
• Installation and Operation Manual

3.2 Installation Requirements

The Jandy AquaPure Ei chlorine generating device must be
installed horizontally with the cell above the pipe to avoid buildup of
fl ammable gases which can result in FIRE OR EXPLOSION.
It is required that the water fl ow pod is installed in the same piping
as the electrolytic cell, without any valves or diverters between them
(see Figure 3).
The fl ow pod must be mounted as shown in Figure 3.
The installation requirements for the Jandy AquaPure Ei chlorine
generating device are as follows:
The power pack must be be installed at least 5 ft. (1.5 m) vertically
off the ground.
The power pack must be be installed at least 10 ft. (3 m) from the
inside wall of your swimming pool or spa.
The cell must be installed on a 2 ½ ft. (0.8 m) horizontal length
of pipe after the heaters, pumps, and fi lters, as the last piece of
equipment in the plumbing system (see Figure 3).
The cell and pod must be installed no more than 15 ft. (4.6 m)
from the power pack (see Figure 3).
The power pack must be installed no more than 3 ft. (1 m) from an electrical outlet.
The pod must be installed upstream from the cell.
WARNING
Tools Needed for Installation
• Cordless Drill (or Power Drill)
• 15/64 in. (6 mm) Hammer Drill Bit (only necessary to drill into
• Pencil or Marking Pen
• Phillips Head Screwdriver or Phillips Head Drill Bit
WARNING
brick or concrete)
Power
Pack
Pod
Figure 3.
AquaPure
®
15 ft. (4.6 m)
MAX

Installation Requirements

®
Cell

Publicité