Bauknecht BHSS 90F L T B K Mode D'emploi page 24

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
T8 button flashing: carry out maintenance of the charcoal filter.
Resetting the filter saturation indicators:
Please note: This must be done with the hood switched on.
Press and hold the T8 button.
Activating the carbon filter saturation indicator
Please note: This must be done with the extraction motor switched off.
This indicator is usually deactivated – press and hold the T3 and T10 buttons simultaneously to activate the function: The buttons will light up
to indicate activation.
To deactivate the function, press and hold the same buttons (T3 and T10) again: The buttons will flash briefly and then switch off to indicate
deactivation.
T9. ON/OFF OPERATING MODE "DAILY AIR SENSE"
The hood will increase the extraction speed to 1 automatically if the sensor in the hood detects that the ambient conditions require this.
If the extraction speed does not change owing to the ambient conditions detected, the hood will switch off after two hours.
The hood will switch off in any case after five hours in use, regardless of the operating mode.
Please note: to make sure this function is used correctly, please configure the parameters for automatic mode first as described in the
relevant section.
T10. ON/OFF OPERATING MODE " INTENSIVE AIR SENSE "
The hood will increase the extraction speed to 5 automatically if the sensor in the hood detects that the ambient conditions require this.
If the extraction speed does not change owing to the ambient conditions detected, the hood will switch off after two hours.
The hood will switch off in any case after five hours in use, regardless of the operating mode.
Please note: to make sure this function is used correctly, please configure the parameters for automatic mode first as described in the
relevant section.
CONFIGURING THE PARAMETERS FOR AUTOMATIC MODE
To make sure that automatic mode is used correctly, you will need to calibrate the hood and select the hob type.
Calibrating the hood
Please note: this must be done with the appliance on standby, i.e. one minute after switching off the motor.
Press and hold the T4 button for five seconds.
Extraction speed 1 will come on and the T4 button will flash to indicate that hood calibration has started (this will take approximately 15
minutes).
Please note: To stop the calibration process, press and hold the T4 button for five seconds. Calibration will then be invalidated and will
therefore need to be repeated.
Please note: Calibration will be carried out automatically when the power supply to the product is switched on for the first time. T4 will flash.
Wait 15 minutes for calibration to complete.
Selecting the hob type
Please note: this must be done with the appliance on standby, i.e. one minute after switching off the motor.
Press and hold the T9 and T10 buttons for five seconds.
The T9 and T10 buttons will light up.
If using gas to power the hob, press the T9 button – the button will flash to indicate that this has been selected.
If using electricity to power the hob, press the T10 button – the button will flash to indicate that this has been selected.
Once pressed, the button will flash for three seconds to indicate that your selection has been saved.
24

Publicité

Table des Matières
loading