R E P L A C I N G T H E B A L L A S T
1
1. Disconnect power at the breaker or
fuse panel before servicing unit.
2
2. Open the ballast housing by removing
the four (4) screws then removing the
cover.
3
3. Disconnect all ballast wiring by pressing
down on connector tabs and pulling wire
straight out.
CAUTION: Never attempt to check operation of the ActivePure® cell(s) by direct
observation. Severe eye damage can result. Use the indicator lamps on the
bottom of the ballast only.
CAUTION: Disconnect power at the breaker or fuse panel before servicing unit. Always
follow OSHA lockout procedures to prevent accidental exposure to electrical energy.
14
4
4. Remove the two (2) nuts
securing ballast to the case.
Remove the ballast.
5
5. Place new ballast into original
location and secure using the
two (2) nuts removed in step 4.