HYUNDAI
• Tilt the machine backwards to gain access to the bleeding point (6).
• Loosen the screw carefully in such a way that the tank is vented
fluently.
• Check the manometer (5). When the tank pressure has dropped
below 0.7 bar, the screw can be removed completely.
• Tilt the machine forward and let the moisture flow from the tank.
Move the tank a few times so that all moisture can flow from the
tank.
• Re-insert the screw and tighten it securely.
Always make sure that all the moisture has been drained
from the tank. Never fully close the bleeding point if you
leave the machine in an area colder than 0 °C.
MAINTENANCE
Warning: switch off the machine before carrying out
maintenance work, remove the plug from the socket and
bleed the tank.
Every use
1. Bleed the tank and drain the moisture.
2. Check for air leaks.
Weekly
1. Clean or replace the air filter if necessary.
Monthly
1. Inspect the non-return valve (clean or replace if necessary). Note:
make sure that the tank is empty for this operation.
2. Test the safety valve (8)manually by pulling the ring.
Three months
1. Tighted the cylinder head bolts.
2. Clean and check valve assembly, replace gaskets/valves if worn
or damaged.
TROUBLE-SHOOTING
If the machine does not work correctly, follow the directions in the
table below to solve the problem. If you can't solve the problem
yourself, contact your dealer.
Motor does not start
• Check that the on/off switch is in the "ON" position.
• Check that the power supply corresponds to the voltage on the
rating plate of the machine.
• Check that the fuses in the meter cupboard are intact.
• Check that no extension cords are used that do not comply
• with the applicable regulations.
• Check that the work environment is not too cold.
Compressor does not supply air
• Check that the pressure is adjusted correctly.
• Check that the machine is switched on.
Air escapes from the tank
• Check if the screw of the tank bleeding point is tightened.
Pressure is too high
• Check if the hose is connected to the correct valve.
• Re-adjust the pressure.
Pressure cannot be adjusted
• Set the pressure to the lowest level.
• Allow the air to escape through the valve of the tank.
• Set the pressure to the required level.
Coupling leaks air
• Connect the air hose with Teflon tape wrapped around the end.
• Apply a small amount of grease to the coupling and move the air
hose several times in and out of the coupling.
TECHNICAL DATA
Mains voltage
V
Mains frequency
Hz
Power input
HP/W
Speed
min
-1
Operating pressure
bar
Capacity
l/min
Operating temperature
°C
Tank
volume
l
max. pressure
bar
environmental-
°C
temperature
LpA (sound pressure)@7m dB(A)
LwA (sound pressure)*
dB(A)
Weight
kg
* Level of sound pressure at the workplace (K=3).
Wear hearing protection!
GUARANTEE
Refer to the enclosed guarantee conditions for the terms and
conditions of guarantee.
ENVIRONMENT
Disposal
Your product, accessories and packaging should be sorted for
environmental-friendly recycling.
Only for EC countries
Do not dispose of power tools into domestic waste. According to the
European Guideline 2002/96/EC for Waste Electrical and Electronic
Equipment and its implementation into national right, power tools
that are no longer usable must be collected separately and disposed
of in an environmentally friendly way.
Subject to change; specifications can be changed without further
notice.
8
55751
55752 55752FH
230
230
230
50
50
50
0.75/550
1.0/750
1.0/750
1,350
1,350
1,350
0 - 8
0 - 8
0 - 8
93
125
125
5 - 40
5 - 40
5 - 40
6
24
24
8
8
8
-10 - 90
-10 - 90
-10 - 90
59
59
59
80
80
80
15
22
22