• Activated carbon/BAC filters have to be checked and exchanged in regular intervals
In case the filter warningdisplay flashes, the following steps are to be followed:
Caution! Filter change with respective protective equipment/clothing only!
LN 230,260,265,610,612,615, OEN710, GL Series, FP Series:
• green LED
• 1
st
yellow LED
= Filter saturation 30% (Are there replacement filters?)
• 2
yellow LED
= Filter saturation 75% Signal: Filter saturated via interface SUB-D 25 !!! Order replacement filter
nd
!!!
• red LED = system will shut down (filter protection)! Filter change is absolutely necessary.
LN 100, LN 220, BF-Series:
• green LED
= Filter OK
• red LED = Filter saturated. Necessarily change filter.
Filter change procedure:
• Disconnect power plug
• Open filter module
• Take out filter
• Check filter and exchange saturated filters by new original filters
• Insert filter
• Close filter module
• Connect power plug
In case it becomes necessary to take off the filter modules, it has to be taken care that the differential
pressure nipples are not damaged and the filter modules are seated correctly.
6.3

Disposal

When disposing off the extraction and filtration system it must be given attention to the fact that the complete filter
equipment is classified hazardous waste that must be disposed of according to the local regulations.
In transportation, all safety instructions from the capter Transportation must be observed.
The system is to be disposed of according to local regulations, taking into regard its contamination (depends on the
extracted substances)
Declaration of RoHS / WEEE conformity
The EC directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic
equipment (RoHs), has come into effect the 1st of July, 2006. It regards the following substances:
Lead (Pb)
17 Filter saturation percentage may vary dependent on the respective filter equipment. Flashing of the 30% warning light after a short
time is not necessarily an indicator for short altogether filter lifetime
6 Maintenance
= Filter OK!
17