5.5 Memory Store

The Solar PV100 can store up to 9 readings.
Press Memory Store button to take a snapshot of the display. Press Memory Recall to
step through each memory location. The small display at the bottom of the screen
shows which location is being shown.
If there is space to store a set of readings, then the Store icon will appear, and the
readings will be stored in the next available slot. If there is no more space then the
buzzer will sound. (Also if there are no valid readings on the display then nothing will be
stored)

5.6 Memory Recall

Each press of the Recall button will show the readings from the next location. The
rd
location number is shown on the bottom of the LCD display. Eg 3:6 means that the 3
location is being displayed and there are 6 locations used.
5% Variation warning.
If the recall data has Voc or Isc reading, then the average of all the stored readings is
calculated. If the current recalled reading is more than 5% different from the average,
then the 5% warning icon will flash.
Average value
Keep pressing the Memory Recall button until the location number is 0:x The display
now shows the average Voc and Isc. of all stored results.

5.7 Memory Clear

Press the Store and Recall buttons together to clear all the user memory locations.