Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Owner's Operation and Installation Manual for the
EX17C (RHFE-434FTA)
EX22C (RHFE-559FTA)
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Register your product at www.rinnairegistration.com
or call 1-866-RINNAI1 (746-6241)
Energysaver
Gas Direct Vent Wall Furnace
Table of Contents .......................... 2
Specifications ................................ 4
Operating Instructions ................... 6
Installation Instructions ................ 15
Consumer Support ...................... 44
French Version ............................ 47
®

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Rinnai Energysaver EX17C

  • Page 1: Table Des Matières

    Owner’s Operation and Installation Manual for the EX17C (RHFE-434FTA) EX22C (RHFE-559FTA) Energysaver ® Gas Direct Vent Wall Furnace Table of Contents ......2 Consumer Safety Information ..3 Specifications ........ 4 Operating Instructions ....6 Installation Instructions ....15 Adjust Gas Pressure Settings ..28 Consumer Support ......
  • Page 2 Snow Accumulation ........11 French Version ..........47-81 Filters ............11 Visual Inspection of Flame ......11 Before Making a Service Call ......12 Fault Codes ............ 13 Restart Function ..........14 Troubleshooting ..........14 Rinnai Corporation EX17C / EX22C Manual...
  • Page 3: Consumer Safety Information

     Any safety screen or guard removed for servicing to the appliance and may result in electric shock. must be replaced prior to operating the appliance.  Do not insert items into the louvers. Rinnai Corporation EX17C / EX22C Manual...
  • Page 4: Specifications

    Propane: 82% Natural Gas: 80% Propane: 82% Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 5: Features

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX17C / EX22C Manual...
  • Page 6: Operating Instructions

    ON THE LEFT AND PULL TOWARD AIR FILTER VENT TERMINAL GAS CONNECTION COMBUSTION AIR/ 1/2” MALE NPT EXHAUST EXHAUST PIPE POWER CORD PLUG 120V AC, 60 Hz COMBUSTION AIR INTAKE HOSE ROOM TEMPERATURE SENSOR/THERMISTOR Rinnai Corporation EX17C / EX22C Manual...
  • Page 7: Control Panel

    If activated while the heater is OFF, then all controls will be locked.  If the heater is turned off while the Child Lock is activated, it cannot be turned on again until the lock is deactivated.  Deactivating the lock releases the control buttons. Rinnai Corporation EX17C / EX22C Manual...
  • Page 8: Setting The Clock

    Timer button. The heater will operate from the start to end times you have entered for that Timer. It will operate at the temperature setting that has been set for the heater. The timer can be set while the heater is operating. Rinnai Corporation EX17C / EX22C Manual...
  • Page 9: Override Function

    2 ºF, effectively saving energy. The room temperature setting will drop up to a total of 4 ºF. The Economy Mode will not operate if the heater is under capacity for the room size. Rinnai Corporation EX17C / EX22C Manual...
  • Page 10: Set Back

    The horizontal louvers (which determines the vertical installed. air flow direction) are fixed and cannot be adjusted. During operation a small amount of condensation is produced in the flue system and drains into the humidifier tray. Rinnai Corporation EX17C / EX22C Manual...
  • Page 11: Care And Maintenance

    All maintenance and service are to be performed by a Dirty filters reduce the air flow qualified service technician, preferably one who has and the appliance’s ability to attended Rinnai service training classes on the Direct produce heat. The filters Vent products. should be cleaned frequently during the heating season.
  • Page 12: Before Making A Service Call

    Unit shuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation EX17C / EX22C Manual...
  • Page 13: Fault Codes

    If the fault code remains assist in diagnosing the problem. The fault code will or returns on the next operation, contact Rinnai or flash in the display on the control panel. When your nearest service agent and arrange for a service making a service call, this code will assist with call.
  • Page 14: Restart Function

    Clean filter Gas Escape Service Call Child Lock Set Cancel Child Lock Gas turned off at meter, tank, Turn gas on or valve. Cancel “ON” Timer or push ON Timer is set override button Rinnai Corporation EX17C / EX22C Manual...
  • Page 15: Installation Instructions

    Installation Instructions General Instructions WARNING  Rinnai suggests that a dedicated electrical circuit with a 120V AC, 60 Hz, 10 amp power source be used. Do not use substitute materials.  This appliance discharges a large volume of warm air next to the floor.
  • Page 16: Gas Connection

    2 in carpeting that is less than 1.2 inches (50 mm) (30 mm) in height. Attach Back Covers (Sides Only) Attach back covers as shown. Engage lugs Rinnai Corporation EX17C / EX22C Manual...
  • Page 17: Dimensions

    29.9 in (760 mm) 10.1 in 257 mm 6.8 in 3.3 in 172 mm 85 mm A full size template is provided on the NOTICE cardboard packaging. DO NOT DISCARD until installation is completed. Rinnai Corporation EX17C / EX22C Manual...
  • Page 18: Flue Terminal Clearances

    Flue Terminal Clearances Rinnai Corporation EX17C / EX22C Manual...
  • Page 19  Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier. Rinnai Corporation EX17C / EX22C Manual...
  • Page 20: Installation Parts

    Screw (M4) (M4) For Back Spacer Set For Flue Manifold Screw Wood Screw (M4) (M4.8 32) For Spacer Bracket Wall Bracket Screws Wall Bracket Spacer Bracket * This plastic tie should be located here Rinnai Corporation EX17C / EX22C Manual...
  • Page 21: Drilling Flue Hole

    The shaded area shows where the flue manifold can be located. Configuration viewed from behind the appliance. Rinnai Corporation EX17C / EX22C Manual...
  • Page 22: Flue Manifold Installation

     This appliance can only be used with one of the not exhaust into other rooms. five types of Rinnai flue kits. The flue kits and their dimensions are listed on the previous page.  The flue manifold is not designed to be positioned ...
  • Page 23 Push the assembly into the terminal tube, ensuring that the seal is in place on the inner tube. Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. 3 screws Rinnai Corporation EX17C / EX22C Manual...
  • Page 24: Extension Kit Installation

     One elbow is shown. One additional elbow may be ance. added.  No elbows are shown. Two additional elbows may  Instructions (1)-(6) must be followed. be added.  Instructions (1)-(6) must be followed. Rinnai Corporation EX17C / EX22C Manual...
  • Page 25 Hose joint another air intake hose into the hose joint. Do not cut the intake hose. Cutting NOTICE the intake hose may result in noise. Air intake hoses Rinnai Corporation EX17C / EX22C Manual...
  • Page 26 Hose Joint - 1.5 in (38 mm) inner dia. Hose Joint - 2.0 in (50 mm) inner dia. Pipe Stopper A Pipe Stopper B Pipe Clamp 2 sets 3 sets 4 sets Wall Fixture Screw A Screw B Rinnai Corporation EX17C / EX22C Manual...
  • Page 27: Connecting The Appliance

    2 screws. Spacer bracket Top Spacer 6. Install the wall bracket with two Top Spacer screws. Attach the heater to the wall bracket with 2 screws. Wall bracket Top Spacer Spacer Bracket Wall Bracket Rinnai Corporation EX17C / EX22C Manual...
  • Page 28: Adjust Gas Pressure Settings

    2.6 in 2.2 in 2.0 in 1.8 in 3.5 in 3.1 in 2.9 in pressure - (101 mm) (65 mm) (57 mm) (52 mm) (47 mm) (89 mm) (80 mm) (72 mm) W.C. High Rinnai Corporation EX17C / EX22C Manual...
  • Page 29: Normal Operating Sequence

    Flame Rod Yellow flames or orange color Final Assembly 1. Install the front panel and bottom cover. 2. If doing a gas type conversion, place the new conversion plate (label) on the front cover. Rinnai Corporation EX17C / EX22C Manual...
  • Page 30: Operating Instructions

    Keep burner the ON/OFF button on the control panel. and control compartment clean. 3. Locate the manual gas valve on the side of the unit. Turn the manual valve clockwise to the full OFF position. Rinnai Corporation EX17C / EX22C Manual...
  • Page 31: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation EX17C / EX22C Manual...
  • Page 32: Wiring Diagram

    OVER HEAT SWITCH 1, 2 gr/y green/yellow THERMAL FUSE CONVECTION FAN MOTOR FUSE SPARKER white ELECTRODE SV1, 2 MAIN SOLENOID VALVE 1, 2 yellow MODULATING SOLENOID COMBUSTION FAN MOTOR gray VALVE orange TRANSFORMER PRESSURE SENSOR brown FLAME ROD Rinnai Corporation EX17C / EX22C Manual...
  • Page 33: Ladder Diagram

    Ladder Diagram Rinnai Corporation EX17C / EX22C Manual...
  • Page 34: Parts List

    Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation EX17C / EX22C Manual...
  • Page 35 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 36 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 37 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 38 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 39 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 40 Parts List (Liste de pieces) Pour les pièces de rechange appelez Rinnai au 1-800-621-9419. Part Number (Numéro de la EX22C-W Name Pièce) EX22C (white) EX17C Rear Panel B ensemble de panneau arrière B 209000091 Frame R armature R 209000092 Frame L...
  • Page 41 RHF1000-132 Connecting Tube tube de connexion 556F-404 Connecting Tube Fixer fixation de tube de connexion 556F-408 * Kit 205000060 includes electrode mounting plate, electrode, electrode packing, and burner box fitting plate assy. Rinnai Corporation EX17C / EX22C Manual...
  • Page 42 205000050 Motor Harness toron de moteur 205000051 High Tension Cord cordon haute tension 205000038 OHS Harness Assy toron de interrupteur de surchauffe 205000052 Convection Motor Harness toron de moteur de convection 205000032 Rinnai Corporation EX17C / EX22C Manual...
  • Page 43: Conversion Kits (Optional) / Kits De Conversion (Facultatifs)

    Conversion Kits (Optional) / Kits de conversion (facultatifs) Model For converting to NG For converting to LPG (Modèle) (Pour la conversion NG) (Pour la conversion LPG) EX17C (RHFE-434FTA) 204000035 204000039 EX22C (RHFE-559FTA) EX22C-W (RHFE-559FTA-W) 204000036 204000040 Rinnai Corporation EX17C / EX22C Manual...
  • Page 44: Consumer Support

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component. All repair parts must be genuine Rinnai parts.
  • Page 45 Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 46: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 47 — L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. INSTALLATEUR : Laissez ce manuel avec l'appareil installé. UTILISATEUR: Conservez ce manuel comme référence ultérieure. Rinnai Corporation EX17C / EX22C Manual...
  • Page 48 Soins et entretien ........... 57 Informations de garantie ........ 80 Avant d’appeler pour de l’aide ....... 58 Garantie limitée ........80, 81 Codes de défauts ........... 59 Fonction de redémarrage ....... 60 Dépannage ............. 60 Rinnai Corporation EX17C / EX22C Manual...
  • Page 49: Sécurité Du Consommateur

     Ne placez pas de conteneurs de liquide sur le redémarrer l’appareil. dessus du chauffage. Déversement d'eau peut causer des dommages considérables à l'appliance  N’insérez pas d’objets étrangers au travers des et peut entraîner des chocs électriques. persiennes. Rinnai Corporation EX17C / EX22C Manual...
  • Page 50: Spécifications

    Gaz naturel Gaz naturel Rinnai poursuit constamment la mise à niveau et l’amélioration de ses produits. De ce fait ces spécifications sont su- jettes à changement sans préavis. Le rendement énergétique de cet appareil mesure l’efficacité thermique du produit en utilisation continue, il a été...
  • Page 51: Caractéristiques

    9 1/2 - 15 3/4 in (240 - 400mm) C Kit de ventil. FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Kit de ventil. FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX17C / EX22C Manual...
  • Page 52: Instructions D'utilisation

    TENIR LES DEUX CÔTÉS ET TIRER VERS VOUS FILTRE À AIR TERMINAISON DE CONNEXIONS DE GAZ VENTILATION 1/2 mâle NPT COMBUSTION/ ÉVACUATION CONDUITE D’ÉVACUATION FICHE PLUG 120V AC, 60 Hz TUYAU D’ADMISSION D’AIR DE COMBUSTION THERMISTANCE Rinnai Corporation EX17C / EX22C Manual...
  • Page 53: Panneau De Commandes

    Si le chauffage a été arrêté pendant que le verrouillage est activé, il ne pourra pas être remis en marche avant que le verrouillage ne soit désactivé.  La désactivation du verrouillage libère les boutons de commande. Rinnai Corporation EX17C / EX22C Manual...
  • Page 54: Mise À L'heure

    Timer choisi. Le chauffage va fonctionner entre l'heure de départ et l'heure de fin que vous avez déterminées pour cette minuterie. Il chauffera à la température de consigne qui a été définie pour l'appareil. Rinnai Corporation EX17C / EX22C Manual...
  • Page 55: Fonction De Surpassement

    Le réglage de la température de la pièce sera au goutte-à- goutte u p pour un total de 4 ºF. Ce mode ne peut pas être activé si le chauffage est sous- dimensionné par rapport à la taille de la pièce. Rinnai Corporation EX17C / EX22C Manual...
  • Page 56: Programmation De Température Minimale

    Ne faites pas fonctionner l'appareil sans que de bac d'humidificateur soit en place. Durant le fonctionnement une petite quantité de condensation est produite dans le système d'évacuation et retombe dans le bac d'humidificateur. Rinnai Corporation EX17C / EX22C Manual...
  • Page 57: Soins Et Entretien

    à produire de la chaleur. Les filtres doivent être préférence a suivi des cours de service chez Rinnai sur ses nettoyés fréquemment pendant la saison de chauffe. Si le produits à ventilation directe.
  • Page 58: Avant D'appeler Pour De L'aide

    Regardez si les filtres sont saturés. Cela peut causer une surchauffe de l’appareil. Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation EX17C / EX22C Manual...
  • Page 59: Codes De Défauts

    à la remise en défaut va clignoter à l’afficheur du panneau de commandes. route, contactez Rinnai ou votre agent de service le plus Quand vous appelez pour une de mande d’intervention, proche pour planifier une intervention.
  • Page 60: Fonction De Redémarrage

    Demande d’intervention Fonction de verrouillage activée ● Déverrouiller Coupure de gaz en amont (compteur, Rétablir l'arrivée du gaz ● réservoir ou vanne) ON Timer est définie. Annuler "ON" bois ou push ● remplacer bouton Rinnai Corporation EX17C / EX22C Manual...
  • Page 61: Instructions D'installation

    La régie de gaz locale vous conseillera sur les réglementations locales.  Rinnai suggère d’utiliser comme source d’alimentation  secteur un circuit dédié à l’appareil (120 V CA, 60 Hz, L’installation doit être conforme aux normes locales, et à...
  • Page 62: Connexion Du Gaz

    40 in ou tapis qui est inférieure à 1,2 (1 m) (50 mm) pouces (30 mm) de hauteur. Fixation des couvercles arrière (Côtés seulement) Fixez les couvercles arrière comme montré ci-contre : Engager les pattes Rinnai Corporation EX17C / EX22C Manual...
  • Page 63: Dégagements En Sortie De Cheminée

    Dégagements en sortie de cheminée Rinnai Corporation EX17C / EX22C Manual...
  • Page 64: Dégagements En Sortie De Cheminée (Suite)

    Permis uniquement si véranda, porche, plate-forme ou balcon est complètement ouvert sur au moins deux côtés sous le  sol.  Pour les distances non spécifiées dans ANSI Z223.1/NFPA 54 ou CSA B149.1, il faut suivre les normes d’installation locales et les contraintes données par le fournisseur de gaz. Rinnai Corporation EX17C / EX22C Manual...
  • Page 65: Dimensions

    10.1 in 257 mm 6.8 in 3.3 in 172 mm 85 mm Un modèle de taille complète est fourni AVIS sur l'emballage en carton. NE JETEZ pas jusqu'à ce que l'installa- tion est terminée. Rinnai Corporation EX17C / EX22C Manual...
  • Page 66: Pièces D'installation

    (M4) (M4.8 32) For Air Intake Clip (pour support de séparateu Wall Bracket Screws (pour support mural) Support Wall Bracket Spacer Bracket Support mural espaceur * Ce lien en plastique doit être situé ici. Rinnai Corporation EX17C / EX22C Manual...
  • Page 67: Perçage Du Trou De Cheminée

    à ce déterminer l'emplacement autorisé du qui est montré quand l’installation est finie. La zone hachurée trou carneau. montre où le collecteur de fumée peut être situé. Configuration viewed from behind the appliance. Rinnai Corporation EX17C / EX22C Manual...
  • Page 68: Installation Du Collecteur De Fumée

    Le collecteur de fumée doit sortir à l’extérieur. N’évacuez L’appareil ne peut être utilisé qu’avec l’un des cinq types pas dans d’autres pièces. de kits de collecteurs de fumée de Rinnai. Ces kits et leurs dimensions sont listés dans la section des spécifi- ...
  • Page 69: Installation Du Collecteur De Fumée (Suite)

    Poussez l’ensemble dans le tube de terminaison en vous assurant que le joint est en place dans le tube intérieur. Fixez la connexion intérieure avec trois vis. Elle peut toujours être tournée pour placer ces vis. 3 vis Rinnai Corporation EX17C / EX22C Manual...
  • Page 70: Installation Du Kit D'extension

    (6) Les extensions de ventilation ne doivent pas être dissimulées selon la norme NFPA 54 et doivent rester accessibles pour permettre leur inspection et réparation. Des caches décoratifs sont disponibles chez Rinnai. Ces illustrations montrent 2 façons possibles d’orienter l’extension de la conduite d’évacuation et du tuyau d’admission d’air en partant du collecteur de fumée.
  • Page 71: Installation Du Kit D'extension (Suite)

    Joint de tuyau d’admission d’air, et en vissant un autre tuyau d’admission Ne coupez pas le tuyau d'admission. AVIS Couper le tuyau d'admission peut Tuyaux d’admission d’air entraîner dans le bruit. Rinnai Corporation EX17C / EX22C Manual...
  • Page 72 Joint de tuyaux - 1.5 po (38 mm) diamètre intérieur Joint de tuyaux - 2.0 po (50 mm) diamètre intérieur Arrêt de tuyau A Arrêt de tuyau B Collier de tuyaux ensemble ensemble ensemble Dispositif mural Écrou Vis A Vis B Rinnai Corporation EX17C / EX22C Manual...
  • Page 73: Branchement De L'appareil

    Mettez en place le support mural avec deux vis. Espaceur supérieur Installez l’espaceur supérieur en insérant sa patte dans Support mural le support mural et en le fixant sur le chauffage avec 2 vis. Espaceur supérieur Patte d’espaceur Support mural Rinnai Corporation EX17C / EX22C Manual...
  • Page 74: Ajustage Et Reglage De La Presion De Gas

    2.2 in 2.0 in 1.8 in 3.5 in 3.1 in 2.9 in differentielle du (101 mm) collecteur - (65 mm) (57 mm) (52 mm) (47 mm) (89 mm) (80 mm) (72 mm) W.C. Haut Rinnai Corporation EX17C / EX22C Manual...
  • Page 75 Assemblée finale 1. Installer le panneau de devant et la couverture de fond. 2. Si vous faites une conversion de type de gaz, placer la nouvelle plaque de conversion (étiquette) sur le capot avant. Rinnai Corporation EX17C / EX22C Manual...
  • Page 76: Instructions De Mise En Œuvre

    (ON/OFF). de contrôle propres. Reportez-vous aux instructions d’installation et d’utilisation. Repérez le robinet de coupure manuelle de gaz sur le côté du chauffage. Tournez-le dans le sens horaire jusqu’à la fermeture totale (position OFF). Rinnai Corporation EX17C / EX22C Manual...
  • Page 77: Schéma En Coupe

    Schéma en coupe Rinnai Corporation EX17C / EX22C Manual...
  • Page 78: Schéma De Câblage

    MOTEUR DE VENTILATEUR DE CONVECTION rouge FUSIBLE ÉCLATEUR blanc ÉLECTRODE SV1, 2 ÉLECTROVANNE 1,2 jaune VANNE MODULATRICE MOTEUR DE VENTILATEUR DE COMBUSTION gris TRANSFORMATEUR DÉTECTEUR DE PRESSION orange ÉLECTRODE DE DÉTECTION DE brun FLAMME UNITÉ AFFICHAGE-COMMANDE Rinnai Corporation EX17C / EX22C Manual...
  • Page 79: Diagramme Logique

    Diagramme logique Rinnai Corporation EX17C / EX22C Manual...
  • Page 80: Informations De Garantie

    Rinnai paiera dans les limites du raisonnable le coût de main-d’œuvre associé à la réparation ou au remplace- ment de toute partie ou composant. Toutes les pièces à réparer doivent être des pièces Rinnai d’origine. Toutes les répa- rations et tous les replacements doivent être effectués par un dépanneur individuel ou une société de dépannage ayant reçu l’autorisation de Rinnai.
  • Page 81: Garantie Limitée (Suite)

    Garantie limitée (Suite) Le remplacement du produit ne peut être autorisé que par Rinnai. La société Rinnai ne permet à aucune personne ou société d’assumer pour elle toute obligation ou responsabilité relative au remplacement d’un produit. Si Rinnai détermine que la réparation d’un produit n’est pas possible, Rinnai le remplacera avec un produit comparable, à...
  • Page 82 Notes Rinnai Corporation EX17C / EX22C Manual...
  • Page 83 Notes Rinnai Corporation EX17C / EX22C Manual...
  • Page 84 • Up to 0.96 Energy Factor (EF) Applications • Internal or External Installation ® • ENERGY STAR qualified models • Pair up with the Rinnai Air Handler for efficient home heating Direct Vent Furnaces • High Efficiency • Vent Terminal A Included • Cool-to-the-touch Cabinet •...

Ce manuel est également adapté pour:

Rhfe-434ftaEnergysaver ex22cRhfe-559fta

Table des Matières