EX38C ................. (RHFE-1005FTA)
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed professional.
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING
THIS HEATER.
This manual provides information on the installation, operation, and maintenance of the heater. For
proper operation and safety, it is important to follow the instructions and adhere to the safety
precautions.
A licensed professional must install the fan convection heater according to the exact instructions
within this manual.
The consumer must read the entire manual to properly operate the heater and to have regular
maintenance performed.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
Register your product at www.rinnairegistration.com or call 1-866-RINNAI1 (746-6241)
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Energysaver ®
Gas Direct Vent Wall Furnace

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Rinnai Energysaver EX38C

  • Page 1 Energysaver ® Gas Direct Vent Wall Furnace EX38C ....(RHFE-1005FTA) Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. —...
  • Page 2: Table Des Matières

    Warranty Information ........42 Care and Maintenance ........11 Limited Warranty ........42, 43 Before Making a Service Call ......12 Fault Codes ............ 13 State Regulations ..........44 Restart Function ..........14 Troubleshooting ..........14 Rinnai Corporation EX38C Manual...
  • Page 3: Consumer Safety Information

     Do not place containers of liquid on top of the  Do not insert items into the louvers. heater. Water spillage can cause extensive damage to the appliance and may result in electric shock. Rinnai Corporation EX38C Manual...
  • Page 4: Safety Features

    88 lbs (40 kg) Noise Level 39 - 46dB Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 5: Features

    C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) Vent A Kit is included with D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) the appliance. Rinnai Corporation EX38C Manual...
  • Page 6: Operating Instructions

    INTO THE TRAY AIR FILTER PIPE STOPPER EXHAUST PIPE GAS CONNECTION 1/2” NPT COMBUSTION AIR INTAKE HOSE PLASTIC TIE FOR AIR INLET AIR FILTER THERMISTOR POWER CORD PLUG 120V AC VENT TERMINAL COMBUSTION / EXHAUST BENT ELBOW Rinnai Corporation EX38C Manual...
  • Page 7: Control Panel

    If activated while the heater is OFF, then all controls will be locked.  If the heater is turned off while the Child Lock is activated, it cannot be turned on again until the lock is deactivated.  Deactivating the lock releases the control buttons. Rinnai Corporation EX38C Manual...
  • Page 8: Setting The Clock

    While in standby, the timer LED will be on with a solid  LO - burner is on minimum combustion light. When operating the LED will be flashing.  60° F - 80° F in one degree increments  HI - burner is on maximum combustion Rinnai Corporation EX38C Manual...
  • Page 9: Override Function

    2. To turn the Economy mode off, press the “Economy” button. The “Economy “ indicator will go out.  The Economy mode can only be turned off while the heater is operating (heating) and when the “Economy” indicator is lit. Rinnai Corporation EX38C Manual...
  • Page 10: Set Back

    If the water overflows from the water level hole, then do not add any more water. Humidifier Tray Max. Fill Line Access Door Pull Filler Spout Do not force door open too far. Close door during operation. Rinnai Corporation EX38C Manual...
  • Page 11: Care And Maintenance

    Dirty filters reduce the air flow and the appliance’s qualified service technician, preferably one who has ability to produce heat. The filters should be cleaned attended Rinnai service training classes on the Direct frequently during the heating season. If the filters Vent products.
  • Page 12: Before Making A Service Call

    High efficiency appliances tend to discharge water vapor on cold days. This is normal. Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation EX38C Manual...
  • Page 13: Fault Codes

    If the fault code remains assist in diagnosing the problem. The fault code will or returns on the next operation, contact Rinnai or your flash in the display on the control panel. When making nearest service agent and arrange for a service call.
  • Page 14: Restart Function

    Air filter blocked Clean filter Gas Escape Service Call Child Lock Set Cancel Child Lock Gas turned off at meter, tank, Turn gas on or valve. Cancel “ON” Timer or push ON Timer is set override button Rinnai Corporation EX38C Manual...
  • Page 15: Installation Instructions

     This appliance must not be connected to a chimney (610 m) elevation. flue serving a separate solid-fuel burning appliance.  Rinnai suggests that a dedicated electrical circuit  A qualified service technician should install the with a 120VAC, 60 Hz, 10 amp power source be appliance and inspect it before use.
  • Page 16: Gas Connection

    10"(250mm) clearances to combustibles shown in the figure must be followed. Also refer to the Safety Behaviors and 0" Practices section. Rinnai recommends 10” (254 mm) clearance from the 2" top and on both sides for servicing. (50mm) 2" (50mm)
  • Page 17: Flue Terminal Clearances

    Flue Terminal Clearances Rinnai Corporation EX38C Manual...
  • Page 18  Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.  For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier. Rinnai Corporation EX38C Manual...
  • Page 19: Dimensions

    Dimensions inches (mm) 12.63 (320) 8.1 (205) 4.5 (113) 13 (330) 36.63 (930) Gas Connection 3.63 (92) Air Inlet Exhaust Pipe Rinnai Corporation EX38C Manual...
  • Page 20: Installation Parts

    Installation Parts The following items are included with the appliance: (Attached to unit) Rinnai Corporation EX38C Manual...
  • Page 21: Drilling Flue Hole

    Template is on the appliance carton/box. Attach Wall Brackets Attach the wall brackets as shown. A template is provided. Attach Back Spacers Attach side back spacers to both sides of the appliance with 2 screws each. Rinnai Corporation EX38C Manual...
  • Page 22: Flue Manifold Installation

     This appliance can only be used with one of the not exhaust into other rooms. five types of Rinnai flue kits. The flue kits and their dimensions are listed on the previous page.  The flue manifold is not designed to be positioned ...
  • Page 23 Push the assembly into the terminal tube, ensuring that the seal is in place on the inner tube. Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. 3 screws Rinnai Corporation EX38C Manual...
  • Page 24: Extension Kit Installation

    (4 m) with 2 bends. The bent pipe attached to the and must be accessible allowing inspection and repair. appliance does not count toward the max limit of 2 Decorative covers are available from Rinnai. bends. Horizontal sections should be sloped 3º to drain condensate.
  • Page 25 Hose joint another air intake hose into the hose joint. Do not cut the intake hose. Cutting NOTICE the intake hose may result in noise. air intake hoses Rinnai Corporation EX38C Manual...
  • Page 26 RFOT 226-001 Pipe Stopper A 1001F-250 Pipe Stopper B FOT 111-6 Top Stopper FOT 062-7 Pipe Clamp FOT 064-11 2 sets 3 sets 4 sets Wall Fixture FOT 064-12 FOT 062-10 Screw A ZAA0420SC Screw B CP-30408 Rinnai Corporation EX38C Manual...
  • Page 27: Connecting The Appliance

    2 screws at each bracket. 6. Attach the back spacer with 3 screws to the top of the appliance. 7. If necessary, the appliance can be leveled using the adjustable legs under the front right and left legs. Rinnai Corporation EX38C Manual...
  • Page 28: Adjust Gas Pressure Settings

    2.85 in 2.73 in pressure - W.C. Low Manifold test 3.77 in 2.99 in 2.69 in 2.45 in 6.38 in 5.62 in 5.06 in 4.58 in pressure - (62 mm) (162 (143 (129 (116 W.C. High Rinnai Corporation EX38C Manual...
  • Page 29 NOTE: If the LED display shows “HF” or “LF” do not touch the ▲ and ▼ buttons or Economy button. In this case push SW1. Final Assembly 1. Install the front panel and bottom cover. 2. Place the conversion plate (label) on the front cover. Rinnai Corporation EX38C Manual...
  • Page 30: Operating Instructions

    Keep burner and control 3. Locate the manual gas valve. compartment clean. See installation and operating instructions. 4. Turn the manual valve clockwise to the full OFF position. Rinnai Corporation EX38C Manual...
  • Page 31: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation EX38C Manual...
  • Page 32: Wiring Diagram

    If any of the original wire as supplied with ELECTRODE SOLENOID VALVE 3 the appliance must be replaced, it must be MODULATING SOLENOID VALVE COMBUSTION FAN MOTOR replaced with type 18 AWG wire or its equivalent. PRESSURE SENSOR FR1, 2 FLAME ROD 1, 2 Rinnai Corporation EX38C Manual...
  • Page 33: Ladder Diagram

    THERMAL FUSE 1, 2 SPARKER FUSE SV1~3 SOLENOID VALVE 1~3 ELECTRODE COMBUSTION FAN MOTOR MODULATING SOLENOID VALVE FAN CONTROL CIRCUIT FR1, 2 FLAME ROD 1, 2 B1~4 BURNER 1~4 CONVECTION FAN PRESSURE SENSOR CONVECTION FAN MOTOR Rinnai Corporation EX38C Manual...
  • Page 34: Parts List

    Parts List / Liste de pièces For replacement parts call Rinnai at 1-800-621-9419. Pour les pièces de rechange, appelez Rinnai au 1-800-621-9419. Rinnai Corporation EX38C Manual...
  • Page 35 Parts List / Liste de pièces Rinnai Corporation EX38C Manual...
  • Page 36 Parts List / Liste de pièces Rinnai Corporation EX38C Manual...
  • Page 37 Parts List / Liste de pièces Rinnai Corporation EX38C Manual...
  • Page 38 Parts List / Liste de pièces Rinnai Corporation EX38C Manual...
  • Page 39 BACK PLATE 209000162 BOTTOM PLATE 208000055 FILTER HOLD SIDE PLATE 208000056 FILTER HOLD CENTER 209000163 STRAIGHTENING PLATE A 209000164 FRAME CENTER PCB UNIT MOUNTING 209000165 ACCESSORY PLATE 209000166 FRAME LOWER LEFT ASSY 209000167 FRAME UPPER LEFT Rinnai Corporation EX38C Manual...
  • Page 40 1004F-2033 AIR INLET PACKING RHF1000-130-E AIR INTAKE HOSE E RHF1000-132 AIR INLET ELBOW 205000076 IGNITER BASE PLATE A 205000077 IGNITER COVER 208000060 COMBUSTION FAN TOTAL ASSY 208000065 EXHAUST ELBOW ASSY 1001F-111X03 COVER RHF1000-145 ELBOW COVER STOPPER Rinnai Corporation EX38C Manual...
  • Page 41 205000041 TF HARNESS 205000087 ROOM THERMISTOR 205000037 IGNITER 205000088 MOTOR HARNESS 205000089 FR HARNESS 205000090 RPM HARNESS 205000091 CONVECTION MOTOR HARNESS 550F-1418 WATER LINE LABEL B 200000064 OPERATION MANUAL 200000066 OPERATION LABEL BRR37-244 ON-OFF VALVE ASSY Rinnai Corporation EX38C Manual...
  • Page 42: Consumer Support

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component. All repair parts must be genuine Rinnai parts.
  • Page 43 Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 44: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 45 NOTES Rinnai Corporation EX38C Manual...
  • Page 46 NOTES Rinnai Corporation EX38C Manual...
  • Page 47: Energysaver

    Energysaver ® Radiateur mural au gaz à ventilation directe EX38C ....(RHFE-1005FTA) Installateur : Laissez ce manuel avec l’appareil. Consommateur : Conservez ce manuel comme référence ultérieure. Si les informations de ces instructions ne sont pas suivies exactement, il peut en résulter un départ AVERTISSEMENT d’incendie ou une explosion, causant des dégâts matériels et des blessures pouvant être mortelles.
  • Page 48 Informations de garantie ........57 ......... 88, 89 Entretien et maintenance Garantie limitée ....58 Avant de demander une intervention ..........59 ......90 Codes de défauts Réglementations provinciales ........60 Fonction de redémarrage ............60 Dépannage Manuel d'EX38C de Rinnai Corporation...
  • Page 49: Informations Pour La Sécurité Du Consommateur

    Ne placez pas de conteneurs de liquide sur le dessus du  N’insérez pas d’objets dans les volets. radiateur. De l’eau renversée peut causer de gros dégâts à l’appareil et peut entraîner une commotion électrique. Manuel d'EX38C de Rinnai Corporation...
  • Page 50: Caractéristiques De Sécurité

    Niveau de bruit 39 - 46 dB Rinnai met constamment à jour et améliore ses produits. C’est pourquoi leurs spécifications sont susceptibles de changer sans préavis. La cote d’efficacité énergétique de cet appareil a été déterminée en laboratoire dans des conditions de fonctionnement continu, indépendamment de tout système installé.
  • Page 51: Caractéristiques

    Kit ventil. C FOT-153 400 - 600 mm (15 3/4 - 23 5/8 po.) Kit ventil. D FOT-154 600 - 800 mm (23 5/8 - 31 1/2 po.) Un kit de ventilation A est livré avec l’appareil. Manuel d'EX38C de Rinnai Corporation...
  • Page 52: Instructions D'utilisation

    NPT 1/2 POUCE TUYAU D’ADMISSION D’AIR DE COMBUSTION COLLIER EN PLASTIQUE POUR ADMISSION D’AIR FILTRE À AIR THERMISTANCE CORDON SECTEUR FICHE SECTEUR 120 V 3 BROCHES TERMINAISON DE VENTILATION AIR DE COMBUSTION / ÉCHAPPEMENT RACCORDEMENT COUDÉ Manuel d'EX38C de Rinnai Corporation...
  • Page 53: Panneau De Commandes

    Si le radiateur est mis à l’arrêt alors que le verrouillage pour enfants était activé, il ne pourra pas être remis en marche avant que ce verrouillage soit désactivé.  La désactivation du verrouillage rend de nouveau opérationnels les boutons de commande. Manuel d'EX38C de Rinnai Corporation...
  • Page 54: Mise À L'heure

    En période d’attente, le voyant DEL de la minuterie sera  60°F - 80°F par incréments de un degree allumé en fixe. En période de fonctionnement il clignotera.  HI - le brûleur est à combustion maximale (plein feu) Rinnai Corporation EX38C Manual...
  • Page 55: Fonction De Surpassement

    économique appuyez de nouveau sur le bouton Economy. Le voyant indicateur correspondant va s’éteindre. Ce mode de fonctionnement économique ne peut ● être désactivé que pendant que le radiateur est en marche avec l’indicateur Economy allumé. Manuel d'EX38C de Rinnai Corporation...
  • Page 56: Seuil Minimal

    Access Door Tirez Pull Filler Spout Bec verseur Do not force door open too far. Ne forcez pas trop loin l’ouverture de porte. Close door during operation. La porte doit rester fermée durant le fonctionnement Manuel d'EX38C de Rinnai Corporation...
  • Page 57: Entretien Et Maintenance

    être menées par un technicien de service qualifié, l’appareil à chauffer. Les filtres sont à nettoyer fréquemment ayant de préférence suivi les cours de formation de Rinnai durant la saison de chauffe. Si les filtres deviennent bloqués sur les produits à ventilation directe.
  • Page 58: Avant De Demander Une Intervention

    Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. surchauffe du radiateur. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Manuel d'EX38C de Rinnai Corporation...
  • Page 59: Codes De Défauts

    Si le code de défaut diagnostiquer le problème. Le code de défaut va clignoter dans persiste ou réapparait au fonctionnement suivant, contactez Rinnai l’afficheur du panneau de commandes. Quand vous appelez pour ou votre agent de service le plus proche pour planifier une une intervention de service, ce code aidera à...
  • Page 60: Fonction De Redémarrage

    Turn gas on compteur, au réservoir ou à la vanne or valve. Désactiver la minuterie ou appuyer sur Cancel “ON” Timer or push Minuterie activée ON Timer is set le bouton de surpassement (Override) override button Manuel d'EX38C de Rinnai Corporation...
  • Page 61: Instructions D'installation

    Les valeurs de puissance d’entrée sont solide. basées sur le niveau de la mer, et ne  Rinnai recommande d’utiliser un circuit d'alimentation doivent être changées jusqu’à une altitude secteur dédié, 120 V/60 Hz, pouvant fournir 10 ampères. de 2 000 pieds (610 m).
  • Page 62: Branchement Du Gaz

    à respecter. Référez-vous également à la section sur les Comportements et pratiques de sécurité. 2" Rinnai recommande un dégagement de 254 mm (10 (50mm) po.) à partir du dessus et des deux côtés pour les 2" interventions de service.
  • Page 63: Dégagements De Sortie D'évacuation

    Dégagements de sortie d’évacuation Manuel d'EX38C de Rinnai Corporation...
  • Page 64 Autorisé seulement si les véranda, porche, plate-forme ou balcon ont une complète ouverture au moins sur deux côtés en- dessous de l’étage.  Pour des dégagements non spécifiés dans ANSI Z223.1/NFPA 54 ou CSA B149.1, ils devront être en conformité avec les normes locales d’installation et les exigences du fournisseur de gaz. Manuel d'EX38C de Rinnai Corporation...
  • Page 65: Dimensions

    Dimensions (mm) pouces 12.63 (320) 8.1 (205) 4.5 (113) 13 (330) 36.63 (930) Connexion de gaz 3.63 (92) Entrée d’air Tuyau d’évacuation Manuel d'EX38C de Rinnai Corporation...
  • Page 66: Pièces D'installation

    Adaptateur de cheminée (Attaché à l'unité) Vis pour supports muraux Arrêt de tuyau A&S Vis pour collecteur de cheminée Vis à bois Vanne manuelle (M4, 8x32) Vis pour supports muraux Manuel d’utilisation Gabarit (sur la boîte) Manuel d'EX38C de Rinnai Corporation...
  • Page 67: Perçage Du Trou De Cheminée

    Fixation des supports muraux Fixez les supports muraux comme c’est montré. Un gabarit est fourni. Support mural Fixation des calages arrière Fixez les calages arrière des deux côtés de l’appareil avec 2 vis chacun. Manuel d'EX38C de Rinnai Corporation...
  • Page 68: Installation Du Collecteur De Cheminée

    Le collecteur de cheminée doit sortir sur l’extérieur. L’appareil ne peut être utilisé qu’avec l’un des cinq types N’évacuez pas dans d’autres pièces; de kit de cheminée Rinnai. Ces kits de cheminée et leurs dimensions sont listés en page précédente. ...
  • Page 69 Poussez l’ensemble dans le tube de terminaison, en vous assurant que le joint est en place dans sur tube intérieur. Fixez la connexion intérieure avec 3 vis. La connexion intérieure peut toujours être tournée pour installer les vis. 3 vis Manuel d'EX38C de Rinnai Corporation...
  • Page 70: Installation De Kits D'extension

    COLLIER DE TUYAU JOINT DE TUYAU TUYAU D’ÉCHAPPEMENT COLLIER DE TUYAU ARRÊT DE TUYAU A JOINT DE TUYAU ARRÊT DE TUYAU A ARRÊT DE TUYAU E ARRÊT DE TUYAU E TUYAU D’ADMISSION D’AIR TUYAU D’ADMISSION D’AIR Manuel d'EX38C de Rinnai Corporation...
  • Page 71: Installation Du Kit D'extension

    Jonction de tuyaux Ne coupez pas le tuyau d’amission d’air. AVIS Cela pourrait générer du bruit. Tuyaux d’admission d’air Manuel d'EX38C de Rinnai Corporation...
  • Page 72: Kits D'extension Et Pièces

    Arrêt de tuyau B FOT 111-6 Arrêt de haut FOT 062-7 Collier de tuyau FOT 064-11 2 jeux 3 jeux 4 jeux Support mural FOT 064-12 Écrou FOT 062-10 Vis A ZAA0420SC Vis B CP-30408 Manuel d'EX38C de Rinnai Corporation...
  • Page 73: Raccordement De L'appareil

    Fixez le calage arrière avec 3 vis en haut de l’appareil. Si nécessaire, l’appareil peut être mis de niveau en utilisant les pieds réglables à l’avant droit et gauche de l’appareil. Jusqu’à 10 mm (3/8 po.) Pied réglable Manuel d'EX38C de Rinnai Corporation...
  • Page 74: Réglages De Pression De Gaz

    Test de pression au collec- 3.77 in 2.99 in 2.69 in 2.45 in 6.38 in 5.62 in 5.06 in 4.58 in teur , pression exprimée en lonne hauteur de co (62 mm) (162 (143 (129 (116 d’eau Plein feu Manuel d'EX38C de Rinnai Corporation...
  • Page 75: Séquence Normale De Fonctionnement

    Placez la plaque de conversion (étiquette) sur le couvercle frontal. REMARQUE : Si l’afficheur à DEL montre “HF” ou “LF”, ne touchez pas aux boutons ▲ et ▼ ni au bouton Economy. Dans ce cas, appuyez sur le micro-commutateur SW1. Manuel d'EX38C de Rinnai Corporation...
  • Page 76: Instructions D'utilisation

    Gardez propres les compartiments de brûleur et de commandes. Localisez la vanne manuelle de coupure de gaz. Consultez les instructions d’installation et d'utilisation. Manuel d'EX38C de Rinnai Corporation...
  • Page 77: Vue En Coupe

    Vue en coupe Manuel d'EX38C de Rinnai Corporation...
  • Page 78: Schéma De Câblage

    Si un des fils d’origine de l’appareil devait ÉLECTROVANNE MODULANTE MOTEUR DE VENTILATEUR DE COMBUSTION être remplacé, il faut le faire avec du fil de qualité 18AWG ou équivalent. CAPTEUR DE PRESSION FR1,2 ÉLECTRODES DE FLAMME 1, 2 Manuel d'EX38C de Rinnai Corporation...
  • Page 79: Diagramme Logique

    MOTEUR DE VENTILATEUR DE COMBUSTION ÉLECTROVANNE MODULANTE CIRCUIT DE COMMANDE DE VENTILATEUR FR1, 2 ÉLECTRODES DE FLAMME 1, 2 B1~4 BRÛLEURS 1 À 4 VENTILATEUR DE CONVECTION CAPTEUR DE PRESSION MOTEUR DE VENTILATEUR DE CONVECTION Manuel d'EX38C de Rinnai Corporation...
  • Page 80: Liste De Pièces

    Liste de pièces Pour les pièces de rechange, appelez Rinnai au 1-800-621-9419. Manuel d'EX38C de Rinnai Corporation...
  • Page 81 Liste de pièces Manuel d'EX38C de Rinnai Corporation...
  • Page 82 Liste de pièces Manuel d'EX38C de Rinnai Corporation...
  • Page 83 Liste de pièces Manuel d'EX38C de Rinnai Corporation...
  • Page 84 Liste de pièces Manuel d'EX38C de Rinnai Corporation...
  • Page 85 PLAQUE DE CÔTÉ SUPPORT DE FILTRE 208000056 CENTRE SUPPORT DE FILTRE 209000163 PLAQUE A DE DRESSAGE 209000164 CENTRE DE CHÂSSIS 209000165 PLAQUE MONTAGE ACCESSOIRE DE PCB 209000166 ENSEMBLE BAS GAUCHE DE CHÂSSIS 209000167 HAUT GAUCHE DE CHÂSSIS Manuel d'EX38C de Rinnai Corporation...
  • Page 86 TUYAU D’ADMISSION D’AIR E RHF1000-132 CODO DE AIRE DE ENTRADA 205000076 PLAQUE A DE BASE D’ALLUMEUR 205000077 COUVERCLE D’ALLUMEUR 208000060 ENSEMBLE DE VENT. DE COMBUSTION 208000065 ENSEMBLE COUDE ÉCHAPPEMENT 1001F-111X03 COUVERCLE RHF1000-145 ARRÊT DE COUVRE-COUDE Manuel d'EX38C de Rinnai Corporation...
  • Page 87: Liste De Pieces

    THERMISTANCE DE PIÈCE 205000037 ALLUMEUR 205000088 HARNAIS MOTEUR 205000089 HARNAIS FR HARNAIS RPM 205000090 205000091 HARNAIS MOTEUR CONVECTION 550F-1418 ÉTIQUETTE CONDUITE D’EAU B 200000064 MANUEL D’UTILISATION ÉTIQUETTE DE FONCTIONNEMENT 200000066 BRR37-244 ENSEMBLE DE VANNE M/A Manuel d'EX38C de Rinnai Corporation...
  • Page 88: Assistance À La Clientèle

    Remède apporté par Rinnai Rinnai va réparer ou remplacer le produit couvert, ou n’importe quels de ses parties ou composants étant défectueux du fait des matériaux ou de la main-d’œuvre, comme c’est explicité dans le tableau précédent. Rinnai paiera des coûts de main- d’œuvre raisonnables associés à...
  • Page 89 _____________ Garantie limitée Le remplacement du produit ne peut être autorisé que par Rinnai. Rinnai n’autorise aucune personne ou société à assumer en son nom une quelconque obligation ou responsabilité de remplacement du produit. Si Rinnai détermine qu’une réparation d’un produit est impossible, Rinnai peut le remplacer par un produit comparable à...
  • Page 90: Réglementations Provinciales

    AVIS AVANT TOUTE INSTALLATION L’appareil Rinnai à ventilation directe doit être installé par un sous-traitant qualifié ou agréé au niveau de la province, ou un installateur Rinnai correctement formé. Si vous n’avez pas reçu la formation appropriée, vous ne devez pas installer cet appareil.
  • Page 91 NOTES Manuel d'EX38C de Rinnai Corporation...
  • Page 92 105514 RHF1005-1231(00) 200000064 3/2015...

Ce manuel est également adapté pour:

Rhfe-1005fta

Table des Matières