GE GTUP270EMWW Instructions D'installation
Masquer les pouces Voir aussi pour GTUP270EMWW:

Publicité

Liens rapides

4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
4" COVER PLATE (IF NEEDED)
(KIT WE1M454)
MATERIALS YOU WILL NEED
4" DUCT
4" DIA. METAL
EXHAUST
CLAMPS (2)
ELBOW
HOOD
OR
4" SPRING
CLAMPS (2)
GLOVES
DUCT TAPE
SAFETY
APPLIANCE POWER
CORD KIT
GLASSES
(NOT PROVIDED)
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
3/4" STRAIN
TYPE AS PER THE
RELIEF
HOUSE RECEPTACLE
UL RECOGNIZED
BEFORE PURCHASING
LINE CORD.

Publicité

loading

Sommaire des Matières pour GE GTUP270EMWW

  • Page 1 MATERIALS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT 4" DIA. METAL SAFETY APPLIANCE POWER 4" DIA. FLEXIBLE METAL (SEMI-RIGID) EXHAUST CLAMPS (2) ELBOW UL LISTED TRANSITION DUCT CORD KIT GLASSES HOOD (IF NEEDED) (NOT PROVIDED) KIT WX08X10077 (INCLUDES 2 ELBOWS) 4"...
  • Page 4 WALL INTERNAL DUCT CHECK THAT EXHAUST OPENING HOOD DAMPER OPENS AND CLOSES FREELY. FLOOR...
  • Page 5 GREEN GROUND GROUND STRAP SCREW STRAIN RELIEF WIRE BRACKET 3/4", UL RECOGNIZED SCREWS STRAIN RELIEF NEUTRAL (White) WIRE 3 #10 AWG MINIMUM COPPER COVER CONDUCTORS OR 120/240V 30A POWER REMOVE GROUND STRAP SUPPLY CORD KIT MARKED FOR USE AND DISCARD. KEEP GREEN WITH DRYERS &...
  • Page 6 27” DRYER EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short Recommended run installations 4" DIA. 4" DIA. 4" DIA. 4" 2-1/2" No. of 90º Rigid Rigid Elbows Metal Metal 56 Feet 42 Feet 46 Feet 36 Feet 34 Feet 28 Feet 32 Feet...
  • Page 7 LEVEL SIDE-TO-SIDE. LEVEL FRONT-TO-BACK. 2 LEVELING LEGS For straight line installation, connect the dryer exhaust to the external exhaust hood using duct tape or clamp. EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP 4" METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP...
  • Page 16 FLOOR...
  • Page 17 VIS VERTE DE MISE A FIXATION LA TERRE A LA MASSE CROCHET SERRECABLE SERRECABLE RECONNU ¾" UL NEUTRE (Blanc) 3 # 10 AWG MINIMUM CONDUCTEURS DE DEPLACEZ LA FIXATION A LA MASSE ET PROTECTION CUIVRE OU 120/240V 30A CORDON DĒBARRASSEZ VOUS EN. GARDEZ LA VIS ELECTRIQUE, KIT MARQUE POUR VERTE DE MISE A LA TERRE CHAUD...
  • Page 19 For straight line installation, connect the dryer exhaust to the external exhaust hood using duct tape or clamp. EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP 4" METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP...
  • Page 28 FLOOR...
  • Page 29 CINTA DE TORNILLO CONEXIÓN VERDE DE A TIERRA CONEXIÓN A TIERRA SOPORTE DEL CABLE DE AMORTIGUADOR CARGA CON REFUERZO AMORTIGUADOR CON REFUERZO TORNILLOS DE 3/4” LISTADO POR UL NEUTRO CABLE DE (Blanco) CARGA RETIRE Y DESCARTE LA CINTA DE CONEXIÓN A TIERRA. CONSERVE EL CABLES ELÉCTRICOS CONDUCTORES DE COBRE TORNILLO VERDE DE CONEXIÓN CABLE DE...
  • Page 31 For straight line installation, connect the dryer exhaust to the external exhaust hood using duct tape or clamp. EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP 4" METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP...