Status message
An error was detected An internal error prevented the self test
Not enough sunlight
Invalid grid condi-
tions
MSD not ready
Tab. 9:
Status messages of errors that prevent the self test from running
72
When the self test has finished, proceed as follows:
7. Press  several times until the status message Self
test passed is displayed (fig. left).
8. Press SET to confirm the result of the self test. The sta-
tus display appears.
Description
from starting.
The self test was not started or was
cancelled due to insufficient sunlight,
especially in the evening / at night.
The self test was cancelled due to inva-
lid grid conditions, e.g. due to insuffi-
cient AC voltage.
The self test was not started because
the inverter was not ready for opera-
tion.
Remedy
Contact your installer if this
error occurs frequently.
Repeat the self test during
the day when the inverter is
feeding the grid.
Repeat the self test later.
Repeat the self test a few
minutes later when the in-
verter is ready for operation
and is feeding.